Transition Networks LAN MASTER 33022.B User Manual

Page 3

Advertising
background image

LANMaster™ T8

8-Port Ethernet™ Repeater Hub

Table of Contents

1 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . 1

The LANMaster T8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Networking the LANMaster T8 . . . . . . . . . . . . . . . . . . . . . . .2
Connectors, Switch, Indicators, . . . . . . . . . . . . . . . . . . . . . .3

2 SITE CONSIDERATIONS. . . . . . . . . . . . . . . . . . . . 4

3 INSTALLATION. . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Unpacking the LANMaster T8 . . . . . . . . . . . . . . . . . . . . . . . .5
Installing LANMaster T8 at Site . . . . . . . . . . . . . . . . . . . . . . .6
Installing Network Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

10BASE-T Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
10BASE-2 Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
10BASE-5 Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
10-Mb/s Network Configuration Guidelines . . . . . . . . . . . . . . .9
Installing Twisted-Pair 10BASE-T Cable . . . . . . . . . . . . . . . . . .11
Installing Thinnet 10BASE-2 Cable . . . . . . . . . . . . . . . . . . . . .12
Installing Thicknet 10BASE-5 Cable . . . . . . . . . . . . . . . . . . . .13

Powering the LANMaster T8 . . . . . . . . . . . . . . . . . . . . . . . .14

4 OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

Monitoring Power LED . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Monitoring Status LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . .15

5 MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . 16

Fault Isolation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Technical Support Contact . . . . . . . . . . . . . . . . . . . . . . . . .16

WARRANTY STATEMENT

. . . . . . . . . . . . . . . . . . . . . . . . . . . 17

ETHERNET CABLE SPECIFICATIONS

. . . . . . . . . . . . . . . . . . 19

LANMASTER T8 8-PORT HUB SPECIFICATIONS

. . . . . . . 21

i

19

ETHERNET CABLE SPECIFICATIONS

AUI Cable and Connector Specifications

The cable is a special 4-pair individually shielded with an overall braided
shield.

Maximum AUI Cable Length:

50 meters (165 feet)

AUI Connector Characteristics:

AUI Port:

Male DB-15 with locking posts.

AUI Connection:

Cable shell must be grounded.

Connector Legend: 1 Logic Ref.

6 Power Return 11 Logic Ref

2 Collision+

7 N/C

12 Receive

3 Transmit+

8 Logic Ref.

13 Power

4 Logic Ref.

9 Collision--

14 Logic Ref.

5 Receive+

10 Transmit-

15 N/C

10BaseFL Cable and Connector Specifications

The physical characteristics of the 10BaseFL cable must meet or exceed IEEE
802.3 10BaseFL specifications.

10BaseFL Cable Characteristics:

Fiber Optic Cable Recommended:

62.5/125 µm multimode fiber

Optional:

100/140 µm multimode fiber

85/125 µm multimode fiber
50/125 µm multimode fiber

Fiber Optic Transmitter Power:

Average power: -15.0 dBm

Peak power: -12.0 dBm ±1dBm

Fiber Optic Receiver Sensitivity:

Average sensitivity: -27.4 dBm

Bit error rate:

10

-10

Maximum Cable Length:

2000 meters (6500 feet)

10BaseFL Connector Characteristics:

ST type connectors (SMA type available upon request)

10BASE-5 Cable and Connector Specifications

The physical characteristics of the 10BASE-5 cable must meet or exceed IEEE
802.3 10BASE-5 specifications.

10BASE-5 Cable Characteristics:

Cable type:

RG8 Solid Coaxial (ThickNet)

Impedance: 50

@ 10 MHz

Capacitance:

26pF/ft

Maximum Cable Length:

500 meters (1650 feet)

Maximum number network connections:

100

Minimum distance between connections:

2.5 meters (8.2 feet)

Terminate 10BASE-5 cable at one end using a 50 ohm terminator and at the

other end using a 50 ohm terminator grounded to earth ground.

Maximum number of terminal devices on Ethernet network:

1024