Note.

When 2 or 3 exchanges are connected by tie-line, select
the Remote response group within the stations connect-
ed to the same exchange.

Remote Response

This feature is available only among stations programmed
for this purpose. When a station at which no one is present

is called by means of a continuous calling tone, remote
response to that call can be made by pressing the( PTT key

from any other station programmed for this function.

Note.

1. This function is only possible when a station is called

by a continuous calling tone.

2. When this function is used from a station with the

Privacy switch ON, press the (PTT) key, after lifting

a station handset or after shifting the Privacy switch
to OFF.

Programming the remote response group

Establish the remote response group of stations and

designate a specific station within the group as a tem-
porary "Master station" and the rest as "Substations".

Note.

Make sure that the temporarily disignated master

always registers his own station number at time of

programming.

Each of "Substation" within the group registers the
"Master" 's number by dialing

I he Master station registers the number of his own

station as follows.

Conversation after Remote response

Dial operation for Remote response

Programming the remote response group (Example)

Cancelling remote response program

Touch dialing at each "Substation"

His own Substation number

cancel Is the Remote response program.