Operation, Cable specifications, Continued product features – Transition Networks CETTF10XX-200 User Manual

Page 4: Fiber cable

Advertising
background image

CETTF10xx-200

6

24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600

Operation

-- Continued

Product Features

AutoCross

The AutoCross feature detects and configures the twisted-pair copper port on
the CETTF10xx-200 media converter to the correct straight-through (MDI) or
crossover (MDI-X) configuration. This feature allows either MDI or MDI-X
cable to connect the media converter to devices such as hubs, transceivers, or
network interface cards (NICs).

NOTE: When AutoCross is disabled, the 10Base-T (copper) port is in MDI-X
(crossover) mode.

Link Pass-Through

The Link Pass-Through feature allows the media converter to monitor both the
fiber and copper RX (receive) ports for loss of signal. In the event of a loss of
an RX signal (1), the media converter will automatically disable the TX
(transmit) signal (2), thus, “passing through” the link loss (3). The far-end
device is automatically notified of the link loss (4), which prevents the loss of
valuable data unknowingly transmitted over an invalid link.

NOTE: An enable/disable switch allows the Link Pass-Through feature to be
disabled. Link Pass-Through may interfere with the Auto-Negotiation feature
of other devices in networks where there are two media converters installed in
series.

4

1

Media

Converter A

Media

Converter B

Near-End

Device

Far-End

Device

original fault

on the copper link

media converter B

disables the copper link

media converter A

disables the fiber TX link

3

2

media converter B

loses the fiber RX link

7

[email protected] -- Click the “Transition Now” link for a live Web chat.

Cable Specifications

The physical characteristics must meet or exceed IEEE 802.3™ specifications.

Fiber Cable

Bit Error Rate:

<10-9

Single mode fiber (recommended):

9 µm

Multimode fiber (recommended):

62.5/125 µm

Multimode fiber (optional):

100/140, 85/140, 50/125 µm

CETTF1011-200

850 nm multimode

Fiber Optic Transmitter Power:

min: -19.0 dBm

max: -14.0 dBm

Fiber Optic Receiver Sensitivity:

min: -32.5 dBm

max: -14.0 dBm

Link Budget:

13.5 dB

CETTF1012-200

1310 nm single mode

Fiber Optic Transmitter Power:

min: -27.0 dBm

max: -10.0 dBm

Fiber Optic Receiver Sensitivity:

min: -34.0 dBm

max: -14.0 dBm

Link Budget:

7.0 dB

CETTF1013-200

850 nm multimode

Fiber Optic Transmitter Power:

min: -19.0 dBm

max: -14.0 dBm

Fiber Optic Receiver Sensitivity:

min: -32.5 dBm

max: -14.0 dBm

Link Budget:

13.5 dB

CETTF1014-200

1310 nm single mode

Fiber Optic Transmitter Power:

min: -27.0 dBm

max: -10.0 dBm

Fiber Optic Receiver Sensitivity:

min: -34.0 dBm

max: -14.0 dBm

Link Budget:

7.0 dB

CETTF1022-200

1310 nm single mode

Fiber-optic Transmitter Power:

min: -15.0 dBm

max: -5.0 dBm

Fiber-optic Receiver Sensitivity:

min: -34.0 dBm

max: -14.0 dBm

Link Budget:

19.0 dB

CETTF1027-200

1300 nm multimode

Fiber-optic Transmitter Power:

min: -19.0 dBm

max: -15.0 dBm

Fiber-optic Receiver Sensitivity:

min: -32.5 dBm

max: -14.0 dBm

Link Budget:

13.5 dB

Product is certified by the manufacturer to comply with DHHS Rule
21/CFR, Subchapter J applicable at the date of manufacture.

The fiber optic transmitters on this device meets Class I Laser safety
requirements per IEC-825/CDRH standards and complies with 21
CFR1040.10 and 21CFR1040.11.

CAUTION: Visible and Invisible Laser Radiation When Open. Do Not
Stare Into Beam Or View Directly With Optical Instruments.

CAUTION: Use of controls, adjustments or the performance of
procedures other than those specified herein may result in hazardous
radiation exposure.

Advertising