Troubleshooting, Contact us – Transition Networks CETTF10XX-200 User Manual

Page 6

Advertising
background image

CETTF10xx-200

10

24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600

Troubleshooting

If the media converter fails, isolate and correct the failure by determining the
answers to the following questions and then taking the indicated action:

1.

Is the PWR LED illuminated?
NO

Is the media converter slide-in-module installed properly in the
chassis?

Is the power cord properly installed in the chassis and at the external
power source?

Does the external power source provide power?

Contact Tech Support: (800) 260-1312, Int’l: 00-1-952-941-7600.

YES

Proceed to step 2.

2.

Is the LKC LED illuminated?
NO

Check twisted-pair cables for proper connection.

Contact Tech Support: (800) 260-1312, Int’l: 00-1-952-941-7600.

YES

Proceed to step 3.

3.

Is the LKF LED illuminated?
NO

Check fiber cables for proper connection.

Verify that TX and RX cables on media converter are connected to
RX and TX ports, respectively, on other device.

Contact Tech Support: (800) 260-1312, Int’l: 00-1-952-941-7600.

YES

Proceed to step 4.

4.

Is the RXC LED flashing?
NO

If there is no activity on the 10Base-T port, proceed to step 5.

If there is activity on the 10Base-T port, disconnect and reconnect the
10Base-T cable to restart the initialization process.

Restart the workstation to restart the initialization process.

Contact Tech Support: (800) 260-1312, Int’l: 00-1-952-941-7600.

YES

Proceed to step 5.

5.

Is the RXF LED flashing?
NO

If there is no activity on the 10Base-FL port, continue below

If there is activity on the 10Base-FL port, disconnect and reconnect
the 10Base-FL cable to restart the initialization process.

Verify that TX and RX cables on media converter are connected to
RX and TX ports, respectively, on other device.

Restart the workstation to restart the initialization process.

Contact Tech Support: (800) 260-1312, Int’l: 00-1-952-941-7600.

YES

Contact Tech Support: (800) 260-1312, Int’l: 00-1-952-941-7600.

11

[email protected] -- Click the “Transition Now” link for a live Web chat.

Declaration of Conformity

Name of Mfg:

Transition Networks
6475 City West Parkway, Minneapolis MN 55344 USA

Model:

CETTF10xx-200 Series Media Converters

Part Number(s):

CETTF1011-200, CETTF1012-200, CETTF1013-200, CETTF1014-200,
CETTF1022-200, CETTF1027-200

Regulation:

EMC Directive 89/336/EEC

Purpose: To declare that the

CETTF10xx-200 to which this declaration refers is

in conformity with the following standards.

CISPR 22 :1993; EN 55022:1994+A1:1995+A2:1997; EN 55024:1998 Class A & B;

FCC Part 15 Subpart B; EN 61000-3-2:1995; EN61000-3-3:1995

I, the undersigned, hereby declare that the equipment specified above conforms to the above

Directive(s) and Standard(s).

October 7, 2001_____

Stephen Anderson, Vice-President of Engineering

Date

Contact Us

Technical Support

Technical support is available 24 hours a day.
US and Canada:

1-800-260-1312

International:

00-1-952-941-7600

Transition Now

Chat live via the Web with Transition Networks Technical Support.
Log onto www.transition.com and click the Transition Now link.

Web-Based Seminars

Transition Networks provides seminars via live web-based training.
Log onto www.transition.com and click the Learning Center link.

E-Mail

Ask a question anytime by sending an e-mail to our technical support staff.
[email protected]

Address

Transition Networks
6475 City West Parkway
Minneapolis, MN 55344, USA
telephone:

952-941-7600

toll free:

800-526-9267

fax:

952-941-2322

Advertising