SHEET TWO

B

Point-to-Point, 4-Wire: Set Switches B-3 & B-4 DOWN(OFF)
Point-to-Point, 2-Wire: Set Switches B-3 & B-4 UP(ON)
Line Terminate DC : Set Switches B-1 & B-2 UP(ON)
Line Terminate AC : set Switches B-2 UP(ON)

For LoopBack Test mode : Set Switches B-3 & B-4 UP(ON)

Set Switch A-4 DOWN(OFF)

Multi-drop (Host), 4-Wire: Set Switches B-3 & B-4 DOWN
Multi-drop (Host), 2-Wire: Set Switches B-3 & B-4 UP

Multi-drop (Slave), 4-Wire: Set Switches B-3 & B-4 DOWN
Multi-drop (Slave), 2-Wire: Set Switches B-3 & B-4 UP

Line Terminate

: Set Switches B-2 & B-1DOWN (OFF) for

all Slaves except UP(ON) on unit furthest
from the Host

Switch A-1:

RTS/CTS Delay: UP = 0 sec; DOWN = 7ms

Switch A-2:

DOWN = TXD enables TX +5ms Select only A-2 or

Switch A-3:

DOWN = RTS enables TX A-3

Switch A-4:

UP(ON) = TX clamps RXD off (ON) in 2-Wire (half duplex) mode

A

B

4 3 2 1 4 3 2 1

A

B

4 3 2 1 4 3 2 1

A

4 3 2 1 4 3 2 1

Earth/Digital Ground (Jump pins if req’d) *

LED 1...

Blinking = POWER ON

Steady = MODEM CONNECTED (CD)

RJ11 Telco Port *

Power Connector

LED 1 *

RS232 Data Port (DB9 female)
for modem configuration only.

RS485
Connection

TX+ TX- RX+ RX-

(* Not on MIU232/485 Converter)

3 & 4 always UP.
1 UP, 2 DOWN when using DB9
for modem configuration.
1 DOWN, 2 UP ~ Modem
connected to RS485. Do not
connect data to DB9

B A

MIUXXX/485 DIP SWITCH SETUP