Telenetics MIU Dial or Leased Line modem with RS-485 User Manual

Page 7

Advertising
background image


Install Op and Diags for MIU Modems and RS485 (0049-0002-010A)

Page 5 of 16

5.

RS485 SPECIFICATIONS

MIUXXXX/485 are low-power Transceiver for RS485 and RS422 communication


Features: Point to Point or Multidrop/Multipolling

Full or Half Duplex

Drivers are short - circuit current limited & protected against excessive

power

dissipation (shutdown will places the drivers in a high - impedance state).

When Drivers are disabled (by TXD), drivers will switch to high

impedance

state.

Note in two-wire or multi-drop/multi-polling networks TX enable by TXD

should be active

Receiver input impedance is 12K ohms.

Reduced slew- rate drivers that minimize EMI and reduce reflections

caused

by improperly terminated cables This will allow error - free

transmitted

data up to 200Kbps

RS485/RS422 standard covers line lengths up to 4000 feet. For line

lengths

greater than 4000 feet a line repeater can be added.

MIUXXXX/485 can drive 4000 feet of 26AWG twisted - pair cable at
200k bps into 120 ohms load.

To minimize reflections, the line should be terminated at both ends. In

multi - polling/multi - drop environments (up to 32 drops) all drops off

the

main cable should be as short as possible.

Only the Master/Host unit and the end of cable unit should be terminated.

Typical Speed versus Distance - (4-wire point to point 26 AWG twisted

cable)

SPEED

DISTANCE

1200bps

6.0 miles(9.6 km)

2400 bps

4.5 miles (7.2 km)

4800 bps

4.0 miles (5.5 km)

9600 bps

2.5 miles (4.0 km)

19,200 bps

1.8 miles (2.9 km)

38,400 bps

1.4 miles (2.1 km)

56,400 bps

1.1 miles (1.8 km)

115,000 bps

0.6 miles (0.9 km)

NOTE: Speed and distances will depend on actual operating

environment.



6. ENVIRONMENTAL SPECIFICATIONS


The CIU/485 (MIUXXX\485) meets the following environmental specifications.

Advertising