*3 Aging cycle count function:

Functions which displays the number of agings carried out on
the Fluorescent indicator tube in numbers. One aging cycle
consists of six discs.

Contents

Name

Code number

No disc in the specified slit

Disc in other slits

No function

No table sensor input

Load in timeover

Load out timeover

Access timeover

High speed search NG

Q data read error

BU operation (From focus search to until signal can be read) timeover

GFS monitor error

Focus cannot be imposed by focus search

DISC sensor check 1

DISC sensor check 2

Table operation check 2

Loading operation check 1

Loading operation check 2

BU related check 1

BU related check 2

BU related check 3

BU related check 4

BU related check 5

BU related check 6

Err 01

Err 02

Err 03

Err 04

Err 05

Err 06

Err *1

Err *2

Err *3

Err *4

Err *5

Err *6

Aging procedure:

Some operating method will be changed depending on if the fol-
lowing jig for the aging mode exists or not.

• Jig

Parts. No

Description

J-2501-123-A

Remote commander (For aging mode)

With remote commander for aging mode:
1. Turn ON the power of the unit. Open the front cover.
2. Press the

[AGING START]

button of the remote commander for

aging mode.

3. When the disc set mode is set, the

· and P LEDs blink.

4. Rotate the JOG dial. The slits (No. 10, 20, 30, 40, 51) for setting

the discs will come forward. Insert the discs into these slits. Do
not set the discs in other slits.

5. Set the use/disuse of the self protection function in errors. Press

the

[REPEAT]

button. When REPEAT is displayed on the fluo-

rescent indicator tube, the self protection function during the
error will become “Use”.
If the REPEAT display is OFF, it means that the function is not
used. (Normally set to “Use” when performing aging.)

6. Press the

· button.

7. The

· LED blinks, the aging mode is set, and aging is started.

8. The aging cycle lasts 3 minutes. When problems occur during

aging, the error number will be displayed on the fluorescent in-
dicator tube, and the

P LED will light up.

(Refer to the following table for the details of the errors.)

9. Aging will be repeated as long as no errors occur.
10. After each aging cycle, the number displayed on the Fluores-

cent indicator tube will increase.

11. To end aging, press the

I

/

u

button

Error Display

Without remote commander for aging mode:
1. Turn ON the power of the unit. Open the front cover.
2. Press the

[PLAY MODE]

,

· , and ≠ buttons in order.

3. When the disc set mode is set, the

· and P LEDs blink.

The following procedure is the same as in the case “With remote
commander for aging mode”.

The * numbers mean the following according to the state of the unit during aging

2 : From checking to end of TOC read
3 : From end of TOC read to end of last track playback
4 : From end of last track playback to end of first track playback

Error code

1 DISCS

TRACK

MIN

SEC

DISC

CD1

5 1

1

1

0 . 0 2

Disc number

Aging carried

(Hexadecimal)

Track number

1 DISCS

DISC

CD1

4 0

1

1Err*01

Disc number

Error code

Advertising