8. Move the holder (sensor) center so that the flat portion center at the top of the D.SENS (CH1) input waveform and the ‘’H” center of

HHOUT (CH2) coincide.

9. Tighten the fixed screw to fix the disc table, then press the

[CLEAR]

button.

10. The disc table rotates in the clockwise direction. Measure the waveform and make sure that the flat portion center at the top of the

D.SENS (CH1) input waveform and the ‘’H” center of HHOUT (CH2) conform.

Note:

During the adjustment mode, the rotational direction is switched each time the

[CLEAR]

button is pressed.

Pressing the

[CHECK]

button enters the loading mode which will be described later. Pressing the

[CLEAR]

button rotates the disc table again.

Contets of the fluorescent indicator tube's display in the loading mode

HHOUT (CH2) waveform

D.SENS (CH1) waveform

Flat portion center of
D. SENS (CH1) waveform

Fixed screw

Holder (sensor)

51

O N

I N

O F F

ALL DISCS

DISC

CD1

Loading OUT
SW condition

Loading
direction

Loading IN
SW condition