System-level application – Telect BCS II User Manual

Page 10

Advertising
background image

1 Descriptions

BCS II Simplex Repeater User Manual

1-6

Telect, Inc.

117209-1 A0

System-Level Application

The simplex repeater regenerates DS3, E3, and STS-1 signals to equal
level point over a distance of up to 900 ft (using RG-59/734 cable). Two
repeaters are required to regenerate both the send and receive sig-
nals and complete the cross-connect.

The repeater regenerates the signal that appears on the IX port and trans-
mits it out the I port for a length dependent upon the type of cable used.
See the installation section to set the module jumpers based on cable
length.

The OX and O ports are passive; therefore, a second repeater is required
to regenerate and transmit the signal in the other direction. Each net-
work element can be located up to 900 ft from the far end repeater’s IX
port.

Simplex

Repeater

I

O

IX

OX

RX

TX

Simplex

Repeater

IX

OX

I

O

NE 2

RX

TX

NE 1

Up to 900 ft (using RG-59/734)

Up to 900 ft (using RG-59/734)