Descriptions

BCS II S

IMPLEX

R

EPEATER

The Broadband Connectivity System II (BCS II) Simplex Repeater (part
# 710-3201-0002) regenerates DS3, E3, and STS-1 signals to allow in-
creased separation of network elements and provides full DSX function-
ality. The module installs in any vertical BCS II chassis or in the Vector
chassis and is always installed in pairs.

Features

Full signal regeneration to equal level point on each circuit

Mini-WECO monitor and I/O jacks

Alarm and tracer lamp LEDs

Full DSX functionality, including patching, monitoring and loop-
backs

S

PECIFICATIONS

Electrical

Monitor Level: 20 dB + 1.5 dB below signal level

Return Loss: < -24 dB at DS3 signal rate

Impedance: 75

Ω (+/- 5%)

Power

Battery Input: A and B redundant, -42 to -58 Vdc

Input Current: 35 mA nominal @ 48V

Internal Fuse: 1/4 amp, not field replaceable