instruction set

The TMS320C2x microprocessor implements a comprehensive instruction set that supports both

numeric-intensive signal processing operations as well as general-purpose applications, such as

multiprocessing and high-speed control. The TMS32020 source code is upward-compatible with TMS320C25

source code. TMS32020 object code runs directly on the TMS320C25.
For maximum throughput, the next instruction is prefetched while the current one is being executed. Since the

same data lines are used to communicate to external data/program or I/O space, the number of cycles may vary

depending upon whether the next data operand fetch is from internal or external memory. Highest throughput

is achieved by maintaining data memory on-chip and using either internal or fast external program memory.

addressing modes

The TMS320C2x instruction set provides three memory addressing modes: direct, indirect, and immediate

addressing.
Both direct and indirect addressing can be used to access data memory. In direct addressing, seven bits of the

instruction word are concatenated with the nine bits of the data memory page pointer to form the 16-bit data

memory address. Indirect addressing accesses data memory through the auxiliary registers. In immediate

addressing, the data is based on a portion of the instruction word(s).
In direct memory addressing, the instruction word contains the lower seven bits of the data memory address.

This field is concatenated with the nine bits of the data memory page pointer to form the full 16-bit address. Thus,

memory is paged in the direct addressing mode with a total of 512 pages, each page containing 128 words.
Up to eight auxiliary registers (AR0-AR7) provide flexible and powerful indirect addressing (five on the

TMS32020, eight on the TMS320C25). To select a specific auxiliary register, the Auxiliary Register Pointer

(ARP) is loaded with a value from 0 to 7 for AR0 through AR7, respectively.
There are seven types of indirect addressing: auto-increment or auto-decrement, post-indexing by either adding

or subtracting the contents of AR0, single indirect addressing with no increment or decrement, and bit-reversal

addressing (used in FFTs on the TMS320C25 only) with increment or decrement. All operations are performed

on the current auxiliary register in the same cycle as the original instruction, following which the current auxiliary

register and ARP may be modified.

repeat feature

A repeat feature, used with instructions such as multiply/accumulates, block moves, I/O transfers, and table

read/writes, allows a single instruction to be performed up to 256 times. The repeat counter (RPTC) is loaded

with either a data memory value (RPT instruction) or an immediate value (RPTK instruction). The value of this

operand is one less than the number of times that the next instruction is executed. Those instructions that are

normally multicycle are pipelined when using the repeat feature, and effectively become single-cycle

instructions.