Adv ance informa t ion – Texas Instruments TMS320 User Manual

Page 64

Advertising
background image

TMS320E25

SPRS010B — MAY 1987 — REVISED NOVEMBER 1990

POST OFFICE BOX 1443

HOUSTON, TEXAS 77001

64

Start

X = 0

Verify

RBIT

Device

Passed

X = 25?

Fail

No

Pass

EPROM

Protect

Setup

Program One

1-ms Pulse

X = X + 1

Protect

Verify

Setup

Device

Failed

Verify

RBIT

Protect

Verify

Setup

Program One

Pulse of 3X-ms

Duration

EPROM

Protect

Setup

Yes

Figure 12. EPROM Protect Flowchart

protect verify

Protect verify is used following the EPROM protect to verify correct programming of the RBIT (see Figure 12).

When using protect verify, Q8 outputs the state of the RBIT. When RBIT = 1, the EPROM is unprotected; when

RBIT = 0, the EPROM is protected. The EPROM protect and verify timings are shown in Figure 13.