Troubleshooting, Ethernet cable specifications, Installing slide-in-module(s) – Transition Networks C/E-100BTX-FRL-03 User Manual

Page 2

Advertising
background image

1. Is the power LED on the media converter illuminated?

NO

Is the Slide-In-Module properly connected to the Media Conversion Center
chasis backplane?

Is the Power Supply Module properly connected both to the Media Conversion
Center chasis backplane and to the AC outlet?

Contact Technical Support at (800) 260-1312/ (800) LAN-WANS.

YES

Proceed to step 2.

2. Is the 100BASE-TX Link LED illuminated?

NO

Check UTP cables for proper connection and pin assignment. (See above.)

Contact Technical Support at (800) 260-1312/ (800) LAN-WANS.

YES

Proceed to step 3.

3. Is the fiber Link LED illuminated?

NO

Check fiber cables for proper connection.

Verify that TX and RX cables on media converter are connected to RX and TX
ports, respectively, on the other 100BASE-FX device.

Refer to Tech Tips available at: http://www.transition.com

Contact Technical Support at (800) 260-1312/ (800) LAN-WANS.

YES

Contact Technical Support at (800) 260-1312/ (800) LAN-WANS.

Troubleshooting

The physical characteristics of the media cable must meet or exceed IEEE
802.3u 100BASE-TX and 100BASE-FX specifications.

ETHERNET CABLE SPECIFICATIONS

100BASE-FX CABLE SPECIFICATIONS

SINGLEMODE
Fiber-optic Cable Recommended:

9 µm singlemode fiber

Fiber-optic Transmitter Power:

min: -15.0

dBm

max: -8.0

dBm

Fiber-optic Receiver Sensitivity:

min: -32.5

dBm

max: -8.0

dBm

Wavelength:

1300nM

Bit error rate:

10

-9

Maximum Cable Distance:

20 kilometers

MULTIMODE
Fiber-optic Cable Recommended:

62.5 / 125 µm multimode fiber

Optional:

100 / 140 µm multimode fiber

85 / 125 µm multimode fiber
50 / 125 µm multimode fiber

Fiber-optic Transmitter Power:

min: -19.0

dBm

max: -14.0

dBm

Fiber-optic Receiver Sensitivity:

min: -32.5

dBm

max: -14.0

dBm

Wavelength:

1300nM

Bit error rate:

10

-9

Maximum Cable Distance:

2 kilometers

100BASE-TX CABLE SPECIFICATIONS
Category 5 wire or better is required. Either shielded twisted pair
(STP) or unshielded twisted pair (UTP) can be used. Use a straight-
through cable configuration (see back page).

CATEGORY 5:

Gauge

24 to 22 AWG

Attenuation

20 dB/1000’ @ 10 MHz

Impedance 100

±10% @ 10 MHz

Maximum Cable Distance:

100 meters (330 feet)

Installing Slide-In-Module(s)

CAUTION: Wear a grounding device and observe electrostatic discharge precautions when
installing Media Converter Slide-in-Module(s) in the 16-Slot Media Conversion Center.
Failure to observe this caution could result in damage to, and subsequent failure of, the
Media Converter Slide-in-Module(s).

NOTE: Media Converter Slide-in-Modules can be installed in any installation slot, in any
order.

To install the Media Converter Slide-in-Module in the E-MCC-1600 chassis:

1. Remove Media Converter Slide-in-Module protective plate from selected installation slot

by removing two screws that secure plate to front of E-MCC-1600. Retain one installation
screw.

2. Carefully slide Media Converter Slide-in-Module into installation slot, aligning Media

Converter Slide-in-Module with installation guides. NOTE: Ensure that the Media
Converter Slide-in-Module is firmly seated against the backplane.

3. Secure Slide-in-Module by installing retained installation screw.

100BASE-FX CABLE CONNECTIONS

Be certain that the correct mode and wavelength fiber cable is used for single-
mode and/or for multimode fiber cable installations.

100BASE-TX CABLE CONNECTIONS

Be certain that the MDI/MDI-X switch located ON the Slide-In-Module circuit
board
is set correctly before installing Slide-In-Module in Media Conversion
Center
. Cable connections between a hub and the media converter require the
MDI/MDI-X switch to be set to MDI. Cable connections between the media
converter and a terminal, transceiver or NIC require the switch to be set to MDI-
X.

Using small flatblade
screwdriver or similar tool,
set MDI/MDI-X switch
position for site installation.

MDI

position

MDI-X

position

toward network connectors

toward chassis

Leave in default position

Set switch

C/E-100BTX-FRL-03