Thermador BOTTOM FREEZER 9000189698 User Manual

Page 25

Advertising
background image

25

Fault

Remedial action

Possible cause

Ice maker is not producing any ice.

The ice cube container is in the false
position.

Reinsert the container and slide it backwards to the end
position (see section Variable interior design").

The water pressure is too low.

Check water pressure. The water pressure must be
between 25 and 120 p.s.i. (1.72ć8.25 bar).

The freezer compartment temperature
is too high.

Check temperature of the freezer compartment.
If required, lower the temperature.

A wrong water valve has been
installedt.

SelfĆtapping valves and 3/16 inch (4.76 mm) saddle
valves reduce the water pressure and may eventually
block the pipe.
The manufacturer is not liable for damage to
property due to an incorrect installation or water
connection.

The ice maker is not producing
enough ice or the ice cubes are

The water pressure is too low.

Check water pressure. The water pressure must be
between 25 and 120 p.s.i. (1.72ć8.25 bar).

g

misshapen.

The freezer compartment temperature
is too low.

Check temperature of the freezer compartment. If
required increase the temperature.

Change the water filter.

Instructions for changing the water filter can be found in
the enclosed installation instructions.

Ice is forming in the supply hose to
the ice maker.

The water pressure is too low.

Check water pressure. The water pressure must be
between 25 and 120 p.s.i. (1.72ć8.25 bar).

The freezer compartment temperature
is too high.

Check temperature of the freezer compartment. If
required, lower the temperature.

Water is flowing out of the
appliance.

The water pipe in the appliance is
defective.

Call customer service immediately.

pp

è Close shutĆoff valve immediately.

The water pressure is too low.

The valve may leak if the water pressure is too low.
The water pressure must be between 25 and 120 p.s.i.
(1.72ć8.25 bar).

A wrong water valve has been
installed.

SelfĆtapping valves and 3/16 inch (4.76 mm) saddle
valves reduce the water pressure and may eventually
block the pipe.
The manufacturer is not liable for damage to
property due to an incorrect installation or water
connection.

Advertising