Troubleshooting

Fault

Check

Action

No power to the
loudspeaker

Is the mains lead plugged in?

Connect the mains lead

Is the mains outlet live?

Check the mains outlet or
switch to another outlet

Is the power switch on?

Press the mains switch

No sound / quiet sound

Is the level control turned
down (anti-clockwise)?

Turn the control slowly
clockwise

Is the source sending a signal? Verify signal at the source

output. Un-mute muted
outputs or mixer channels.
Check cables and/or replace

Is the mic/line switch set
incorrectly?

Change mic/line setting to
correct source

No sound from
connected microphone

Is the microphone a
condenser type needing
phantom power?

Milan does not supply +48v
phantom power. Use a
dynamic microphone or
connect to a mixer with
phantom power

No sound although
loudspeaker is on

Is the loudspeaker in protect
mode?

Turn off the mains switch,
unplug the loudspeaker before
reconnecting

Does the loudspeaker remain
in protect mode?

Refer to qualified service
personnel

Distorted sound

Is the input signal level too
high?
Is the mic/line switch set
incorrectly?

Reduce mixer or preamp level

Change mic/line setting to
correct source

Distorted sound, limit
LED is on continuously

Are the volume controls set
too high?

Reduce volume controls or
use additional loudspeakers

Hum or noise

Are the connected sources
balanced?

Use balanced cables and 3-
pole connectors wherever
possible. Check wiring.

Ground loops?

Lift audio ground on affected
device with adapter

Are signal cables near or
running parallel to mains
cables?

Move signal cables