Installation, Connection to the power supply, Warning – Thermador T24IR User Manual

Page 7: Caution, Installation room, Installation cavity, Furniture/fixtures, Base, Installing and connecting the appliance

Advertising
background image

7

Installation

d

WARNING

d

Do not install the appliance:
- outdoors,

- in an environment with dripping

water,

- in rooms which are at risk of

frost.

The appliance is very heavy ć for

empty weight see the following

table:
Refrigerator 24" 310 lbs / 140 kg

Refrigerator 30" 350 lbs / 158 kg

Installation room

The appliance should be installed in

a dry, well ventilated room.
The ambient temperature should not

drop below 55

°

F (13

°

C) or rise

above 110

°

F (43

°

C), otherwise

malfunctions may occur.
The installation location should not

be exposed to direct sunlight and

not placed near a heat source, such

as an oven, radiator, etc.

If installation next to a heat source is

unavoidable, use a suitable

insulating plate or observe the

following minimum distances from

the heat source:
- 1.2" (3 cm) from an electric

cooker,

- 12" (30 cm) from an oil or

solidĆfuel cooker.

Installation cavity

It is important to observe the

specified dimensions of the

installation cavity for a troubleĆfree

installation of the appliance and for

the subsequent general view of the

furniture front.
In particular ensure that the cavity is

square. Squareness can be checked

by suitable means, e.g. spirit level,

diagonal measurements, etc.

Furniture/fixtures

The new appliance will be mounted

securely to adjacent and overhead

furniture/fixtures.
For this reason it is essential that all

attachable furniture/fixtures are

connected securely to the base or

the wall by suitable means.

Base

To ensure that the appliance is

installed securely and functions

properly, the base must be flat and

level.
The base must be made of a hard,

rigid material.
The installation area must be the

same height as the rest of the room.
On account of the heavy weight of

a fully loaded appliance,

a loadĆbearing base is required.
For fullyĆloaded weight see the

following table:
- Refrigerator 24" 890 lbs / 400 kg
- Refrigerator 30" 1110 lbs / 500

kg

If in doubt, contact an architect or

a building expert.

Installing and

connecting the

appliance

d

CAUTION

d

Have the appliance installed by an

electrician according to the

enclosed installation instructions.

After installing the appliance, wait at

least before switching on the

appliance. During transit the oil in

the refrigeration system may have

moved.
Before switching on the appliance

for the first time, clean the inside of

the appliance.

Connection

to the power

supply

d

WARNING

d

Avoid Electrical Shock

Hazard

- Plug into a grounded 3 prong

outlet.

- Do not remove ground prong.
- Do not use an adapter.
- Do not use an extension cord.
Failure to follow these instructions

can result in death, fire, or

electrical shock.
Improper connection of the

equipment grounding conductor

may result in electric shock. Have

the appliance checked by a

qualified electrician or service

technician if you are in doubt as

to whether the appliance has

been properly grounded.

The appliance comes with an UL

listed, 3Ćwire power supply cord.
The appliance requires a 3Ćwire

receptacle.
The receptacle must be installed by

a licensed electrician only.

Advertising