Locate the four M10 x 40mm hex screws from the fixings kit and insert these through the
enclosure connector into the rigging points on the two outside cabinets, together with four
M10 shakeproof washers.

Use the four M10 x 35mm hex screws from the fixings kit to lock the enclosure connector to
the rear brace together with four flat washers and four M10 nylock nuts.

All fixings should be thread-locked and torqued to 25Nm.