Chapter 12: system functions and remote control – Telos Zephyr Xstream User Manual

Page 257

Advertising
background image

USER’S MANUAL

Section 12: System Functions and Remote Control 245

12 System Functions and Remote

Control

12.1 Ancillary Data

Serial Data Transmission

The serial interface can be used to control the Zephyr Xstream, i.e. to change transmission 
modes or request status information.  A Telnet session can also be used to perform this 
function. 

The serial interface can be switched to transparent or ancillary data mode using the atdt 
command.

  

While the transparent mode is active, all data sent to the Zephyr Xstream's serial input is 
inserted into the coded audio signal and – provided there is an valid ISDN,

 

V.35, or IP connection 

– transmitted to the receiving Zephyr.  The latter will extract ancillary data information from the 
coded audio signal and output it on its own serial interface if it is in transparent mode. 

• The ancillary data transmission is fully bi‐directional and does not affect any 

ongoing audio transmission.  The necessary bitrate to transmit ancillary 
data, however, is taken from the overall available line bitrate. 

• Ancillary data that is fed into the Zephyr Xstream without having a 

connection will be lost. 

• In Dual/Mono transmit mode ancillary data is transmitted to both sites. In 

Dual/Mono receive mode ancillary data line 2 is ignored. 

• The ancillary data channel is an on‐demand service, which means that the 

audio bitrate is only reduced if necessary.  However, data can be 
transmitted continuously at up to 9600 kbps (Stereo and Mono‐128) or 
2400 kbps (Mono‐64 and stereo‐64).  See below. 

• Ancillary data is only available in certain modes, as outlined below: 

Advertising