Specifications, Corded models) – Tripp Lite APS PowerVerter User Manual

Page 14

Advertising
background image

14

Specifications

(Corded Models)

CORDED MODELS:

APS 1012

APS 1024

Weight:

26.4 lbs.

26.4 lbs.

INVERTER
Continuous power (@ 20° C):

900 W

1000 W

Surge power (5 seconds):

1800 W

2000 W

Efficiency (Full Load):

90%

90%

Minimum DC Fuse Rating:

225A

125A

DC Input Current @ Nominal V DC

Full Load

95 A

47 A

No Load

2.2 A*

1.3 A*

Nominal Input Volts:

12 VDC

24 VDC

DC Input Voltage Range:

10-15 VDC

20-30 VDC

Nominal Output Volts:

120 VAC ±5%

120 VAC ±5%

Nominal Output Frequency:

60 Hz ±.3%

60 Hz ±.3%

BATTERY CHARGER

Charging Capacity DC:

30 A

15 A

Maximum Cable Length

2 ft.

7 ft.

Acceptance Volts VDC:

Selectable

Selectable

14.4 V**/14.2 V Wet**/Gel

28.8 V**/28.4 V Wet**/Gel

Float Volts VDC (w/gel):

13.3 V (13.6 V)

26.6 V (27.2 V)

Input Voltage AC:

120 V

120 V

Input Current AC:

8 A

8 A

LINE VAC OPERATION

Minimum Input AC Volts:

Selectable 75**,85, 95, or 105 VAC Selectable 75**,85, 95, or 105 VAC

Maximum Input AC Volts
(Continuous, Charger at Maximum):

Selectable 135** or 145 VAC

Selectable 135* *or 145 VAC

Maximum Input Current
(Continuous, Charger at Maximum):

12 A

16 A

Input Frequency:

60 Hz ±10%

60 Hz ±10%

Maximum Output AC (Continuous):

8.3 A

8.3 A

Automatic Transfer Time:

4-6 ms

4-6 ms

*Load sense can reduce this to 1/30 of the listed current. **Factory default setting.

200103046 120V APS MV-cabinetEn-Sp 93-1911.qxd 7/2/01 10:18 AM Page 14

Advertising