Test Procedure

2-4

2.2.1

Equipment

1) Power source: current-limited 5-V lab supply with its current limit set to

1.0 A

±

0.1 A

2) Two Fluke 75, equivalent or better

3) Oscilloscope – TDS220 or better

4) Load test board (See Figure 2–1.)

Figure 2–1. Load Test Board

C1
2000

µ

F

25 V

8

Power Supply

5.1 V

±

0.1 V

Current Limit

1 A

±

0.1 A

+

DMM

DC+

DC–

UUT

bq24010/2 EVM

BAT+

BAT–

BAT+

BAT–

DMM

Volts

S4

R3
3 k

0.25 W

S1

R6

10 k

0.25 W

S2

R4
66.5

0.25 W

7 6 5

R5
66.5

0.25 W

Q1
Si4410DY

3 2 1

D1
1N4148

S3

R7

10 k

0.25 W

8 7 6 5

Q2
Si4410DY

3 2 1

4

4

R1
5

5 W

2.2.2

Equipment Setup

1) Connect the load board to the BAT+ and BAT–. Set SW1 through SW4 in

the closed position.

2) Connect a voltage meter to the BAT+/BAT– output to monitor the output

voltage (Range is 0 to 5 V).

3) Set the lab supply for 5.1 V

±

0.1VDC, 1.0

±

0.1 A current limit and then turn

off supply. Connect the source supply to a current meter and to J1, noting
polarity. (You may use an internal source current meter if it has 5% or
better accuracy.)

4) Install shunt jumpers on the LED pins 1 and 2 of each header J4, J5, and

J6.

5) Connect the scope to the output, BAT+.

2.2.3

Procedure

1) Ensure that equipment setup steps are followed. (Switches should be in

the closed position, shunts installed, and power source set to 5.1V/-0.1V.
Turn on the power source.

2) Verify that output voltage BAT+ charges up to between 2.5 V and 2.9 V,

and the red LED (D1) and green LED (D3) are lit.

3) Open switch SW2, and then close switch SW2.