Texas Instruments bq24010/2 User Manual

Page 13

Advertising
background image

Test Procedure

2-5

Test Summary

4) Verify that output voltage BAT+ settles between 3.2 V and 3.95 V.

5) Verify that the input current is between 0.69 A and 0.75 A.

6) Open switch SW3.

7) Verify that the input current is between 100 mA and 150 mA.

8) Verify the output voltage BAT+ is between 4.150 VDC and 4.250 VDC.

9) Open switch SW2.

10) Verify with a scope (250 ms/div, 1 V/div) that output BAT+ charges and

discharges are between the maximum limits of 3 V and 4.35 V, with a
period between 600 ms and 850 ms.

11) Verify that the LEDs flash between RED (D1) and GREEN (D2, mostly on

green).

12) Open switch SW4 and verify that D1 and D2 are off and D3 is on.

13) Verify, with a scope on BAT+, a square wave between the maximum limits

of 1.3 and 4.35 VDC and a frequency between 3.5 and 4.5 Hz.

14) Close switches SW2, SW3, and SW4 (all switches should be closed now)

and power down the supply.

15) The EVM is good if all tests are passed.