CU111 Specifications

1.Overview

Connecting the RS232C/RS485 multi-drop adapter (CU111) to the T1’s programmer port, you
can use the RS485 computer link function.
By this function, long-distance and one -to- N communications become available.

2.Specifications

(1)Function specification

Item

Specification

Connection

RS232C

DIN - 8pin (T1 programmer port connector)

RS485

Removable terminal block 6pin

Length of T1 connection cable 30cm
Status LEDs

3 (Refer to the following table)

Isolation

Non isolation between RS232C and RS485

Power Supply

5Vdc from T1 main unit

Current consumption

75mA

Size

30mm(W)

×

90mm(H)

×

75mm(D) (except cable)

(2)Transmission specification

Item

Specification

Interface

Conforms to RS232C (T1 side)
Conforms to RS485 (Host side)

Transmission distance

30cm (between T1 and adapter)
Max. 1km (RS485 )

Transmission speed

9600 bps

Framing

Start bit 1bit (Fixed)
Dta bit 8bits (Fixed)
Parity Odd parity/ Non (automatic detection)
Stop bit 1bit (Fixed)

Number of stations

Max. 32

(3)RS485 transmission cable

Shieled twisted cable which conforms to the RS485, should be used for communication
cable. It’s recommended that 0.9mm diameter or more, 3 pairs or more cables are used.

(4)Operation Status LEDs

Name

Direction

LED Status

(color)

Lit

Not Lit

POWER
(green)

5V power is normal and
connected to T1

5V power is not normal.

RXD
(green)

Host

T1

Data receiving
(RXD = 0)

Data not receiving
(RXD = 1)

TXD
(green)

T1

Host

Data transmitting
(TXD = 0)

Data not transmitting
(TXD = 1)