Special Tools

NOTE: Order special tools from the TO R O S P E C IA L
TO O L S A N D A P P L IC AT IO N S G U ID E (C O M M E R C IA L
P R O D U C T S )
. Some tools may be listed in the
Greensmaster 3100 Parts Catalog. Some tools may
also be available from a local supplier.

Hydraulic Tester (Fig. 6)

Figure 6

You must have o-ring face seal (ORFS) adapter fittings
for this tester to use it on the Greensmaster 3100.

1. INLET HOSE: Hose connected from the system
circuit to the inlet side of the hydraulic tester.

2. LOAD VALVE: If required, upon turning the valve to
restrict flow, a simulated working load is created in the
circuit.

3. LOW PRESSURE GAUGE: Low range gauge to
provide accurate reading at low pressure, 0 - 1000 psi
(0 - 6895 kPa).

This gauge has a protector valve which cuts out
when pressure is about to exceed the normal range
for the gauge. The cutout pressure is adjustable.

4. HIGH PRESSURE GAUGE: High range gauge to
accommodate pressure beyond the capacity of the low
pressure gauge, 0 - 5000 (0 - 34475 kPa).

5. FLOW METER: This meter measures actual oil flow
in the operation circuit. The reading is given in gallons
per minute (GPM) and liters per minute (LPM) with a
gauge rated at 15 GPM (57 LPM).

6. OUTLET HOSE: Hose from the outlet side of the
hydraulic tester to be connected to the hydraulic system
circuit.

Load Valve

Outlet
Hose

Flow Meter

High Pressure
Gauge

Inlet Hose

Gauge
Protector Valve

Low Pressure
Gauge

Greensmaster

®

3100

Page 4 - 13

Special Tools