Electrical connections, Permanent connection – Tricity Bendix BIW 85 User Manual

Page 30

Advertising
background image

30

Electrical connections

Any electrical work required to install this appliance
should be carried out by a qualified electrician.or
competent person

WARNING: THIS APPLIANCE MUST BE

EARTHED.

The manufacturer declines any liability should

this safety measure not be observed.

Before switching on, make sure the electricity supply
voltage is the same as that indicated on the appliace
rating plate (the plate is sticked to the rear of the
appliance).

The appliance is supplied with a 13 amp plug fitted. In
the event of having to change the fuse in the plug
supplied, use a 13 Amp BS1362 fuse. Only ASTA or
BSI approved fuses must be used.

Should the plug need to be replaced for any reason,
proceed as described below.

The wires in the mains lead are coloured in accordance
with the following code:

Green and Yellow

- Earth

Blue

- Neutral

Brown

- Live

Connect the green and yellow (earth) wire to the
terminal in the plug which is marked with the letter «E»
or the earth symbol

or coloured green and yellow.

Connect the blue (neutral) wire to the terminal in the
plug which is marked with the letter «N» or coloured
black.

Connect the brown (live) wire to the terminal in the plug
which is marked with the letter «L» or coloured red.

The plug must not be used if the fuse cover/carrier is
lost. The cover/carrier is indicated by the coloured insert
at the base of the plug.

A replacement cover/carrier must be obtained from your
local Bendix Service Centre, whose address are listed in
this instruction manual.

WARNING: a cut off plug inserted into a 13

amp socket is a serious safety (shock) hazard.

Ensure that the cut off plug is disposed of

safely.

GREEN & YELLOW

BROWN

CORD CLAMP

BLUE

13

A

P1041

E

N

L

Permanent connection

In the case of permanent connection it is necessary that
you install a double pole switch between the appliance
and the electricity supply (mains), with a minimum gap
of 3 mm between the switch contacts and of a type
suitable for the required load in compliance with the
current electrical regulations.

The switch must not break the yellow and green earth
cable at any point.