Troubleshooting guide – U-Line 2275DWRWS User Manual

Page 22

Advertising
background image

22

2275DWRWS, 2275DWRWOL

Troubleshooting Guide

DANGER

ELECTROCUTION HAZARD
Never attempt to repair or perform maintenance on
the unit until the main electrical power has been
disconnected.

Troubleshooting - What to check when problems occur:

PROBLEM

POSSIBLE CAUSE

REMEDY

Unit does not operate and
electronic display is blank.

No electrical supply

Plug unit in or check circuit breaker.

No interior light

Loose or burned out bulb

Tighten or replace bulb (See MAINTENANCE; LIGHT
BULB REPLACEMENT).

Unit not cold enough. Check
temperatures (See OPERATION for
approximate temperatures).

Control set too warm

Set control to a cooler setting (See OPERATION). Allow
24 hours for temperature to stabilize.

Airflow to front grille blocked

Airflow must not be obstructed to front grille (See
OPERATION).

Dirty condenser coils

Clean condenser (See MAINTENANCE; CONDENSER
CLEANING).

Door gasket not sealing properly

Door adjustment required (See MAINTENANCE; ADJUST
DRAWERS).

Item(s) interfering with drawer

Reposition or remove item(s).

Inaccurate temperature reading

Properly check temperature (See OPERATION).

Unit is too cold. Check temperatures
(See OPERATION for approximate
temperatures).

Control set too cold

Set control to a warmer setting (See OPERATION). Allow
24 hours for temperature to stabilize.

The unit frosts up.

High ambient temperatures or
humidity

Defrost unit manually (See MAINTENANCE;
DEFROSTING).

Noise during operation.

Certain sounds are normal.

Soft sounds from the fan and water/dropping sounds
from the ice maker will be heard.

Drawer(s) can't close.

Item(s) interfering with drawer

Adjust items in drawer(s).

Unit not level

Make sure unit is level (See LEVELING, page 14).

ULIN_016357_30179.fm Page 22 Thursday, February 1, 2007 1:24 PM

Advertising
This manual is related to the following products: