Page 56


Write : 0: Clear flag 1: Ignored

FER

[13]

Receive data framing error
Read : Current status
Write : 0: Clear flag 1: Ignored

PER

[14]

Receive data parity error
Read : Current status
Write : 0: Clear flag 1: Ignored

- [15]

Reserved

008h Receive_Buffer_Sta

tus_Control

RBUF_ST

[0..8]

SIO receive buffer status
Read :
Valid data size of current receive buffer
Write : Ignored

RBUF_CNT

[8..15]

SIO receive buffer control
Read : Remain data size for read
Write : Set input data size

- [16..31]

Reserved

00Ch Transmit_Buffer_St

atus_Control

TBUF_ST

[0..7]

SIO ouput buffer status
Read :
Available data space of transmit buffer
Write : Ignored

TBUF_CNT

[8..15]

SIO output buffer control
Read : Written data size to buffer
Write : Set output data size for transmit

- [16..31]

Reserved

010h

..

0FFh

Reserved

100h SIO_Data_Register

Char_0

[0..7] Chracter_0

Read : Read character from receive buffer
Padding data, if data is not available
Write : Character to transmit buffer
padding data if data is invalid

Char_1 [8..15]

Chracter_1
Read : Read character from receive buffer
+1 Padding data, if data is not available
Write : Character to transmit buffer +1
padding data if data is invalid

Char_2 [8..15]

Chracter_2
Read : Read character from receive buffer
+2 Padding data, if data is not available
Write : Character to transmit buffer +2
padding data if data is invalid

Char_3 [16..31]

Chracter_3
Read : Read character from receive buffer
+3 Padding data, if data is not available
Write : Character to transmit buffer +3
padding data if data is invalid

104h

..

1FFh

SIO_Data_Register

_Alias

[0..31]

Alias SIO_Data_Register area for block
transfer