Installation – United States Stove Company KING/ASHLEY PELLET STOVE 5500M User Manual

Page 8

Advertising
background image

8

USSC

Installation

vENT TErMiNATiON CLEArANCES:

A)

Minimum 4-foot clearance below or beside any door or window that opens.

B)

Minimum 1-foot clearance above any door or window that opens.

C)

Minimum 3-foot clearance from any adjacent building.

D)

Minimum 7-foot clearance from any grade when adjacent to public walkways.

E)

Minimum 2-foot clearance above any grass, plants, or other combustible materials.

F)

Minimum 3-foot clearance from an forced air intake of any appliance.

G)

Minimum 2-foot clearance below eves or overhang.

H)

Minimum 1-foot clearance horizontally from combustible wall.

I)

Must be a minimum of 36-inches above the roof and 24-inches above the highest point or the roof within 10-feet.