Operating your water heater, Warning, Before using – Univex EPX-80DHPT User Manual

Page 11: Water temperature regulation

Advertising
background image

11

OPERATING YOUR WATER HEATER

Before Using

Make sure the water heater has been properly

1.

installed. See “Installing Your Water Heater” section.
Make sure the air filter is correctly seated, as it may

2.

shift during shipping or installation. See “Repair Parts
Illustration” section.
Completely fill the tank with water (See “Water Piping”

3.

section).
After the water heater tank is completely filled with water,

4.

connect electrical power to the water heater.
Read the “Water Temperature Regulation” section of this

5.

manual.

If you do not fully understand these instruction,

contact a qualifi ed person.

Press the power button (See Figure 10) to turn the water

6.

heater on and allow it to run a system diagnostic. This
typically takes eight minutes. Once complete, proceed to
the next step.
NOTE:

If the system diagnostic yields any codes,

reference the Diagnostic Code section in this manual.
Adjust the thermostat to the desired temperature

7.

setting as described under “Adjusting the User Interface
Module/Operational Modes” section.

IMPORTANT:

Do not attempt to operate this water heater

if the unit has been submerged, subjected to fl ooding, or
surrounding insulation has been exposed to water in any
way.
Do not attempt to repair a unit subjected to fl ood conditions.
Water heaters subjected to fl ood conditions or any time the
unit has been submerged in water require replacement of
the entire water heater.

Safety Shut-off (ECO)

This water heater is designed to automatically shut-off in the
event that the water temperature exceeds 190°F or 87.8°C.
A temperature limit switch or ECO (Energy Cut Off) is used
to shut off the power to the system if the water temperature
exceeds 190°F or 87.8°C (See “Water Temperature
Regulation” section). To reset the ECO disconnect power at
the circuit breaker/fuse box then remove the upper access
panel. Reset the ECO by fi rmly pushing in the red reset
button located on the ECO block. If the ECO continues
to shut-off the water heater contact a qualifi ed person for
service.

Water Temperature Regulation

Water temperature over 125°F can cause
severe burns instantly or death from scalds.

Children, disabled and elderly are at highest

risk of being scalded.

Feel water before bathing or showering.

Temperature limiting valves are available.

WARNING

The water heater is adjusted to a temperature setting of

no higher than 120°F when it is shipped from the factory.

Water temperature can be regulated by adjusting the User

Interface Module to the preferred setting as shown in

“Adjusting the User Interface Module/Operational Mode”

The preferred starting point is 120°F. There is a hot water

scald potential if the temperature set point is set too high.

IMPORTANT:

Adjusting the set point above 120°F on the

User Interface Module will increase the risk of scald injury in
the times shown below.

Table 1

Water

Temperature °F

Time for 1st

Degree Burn

(Less Severe Burns)

Time for

Permanent Burns

2nd & 3rd Degree

(Most Severe Burns)

110

116

116

122

131

140

149

154

(normal shower temp.)

(pain threshold)

35 minutes

1 minute

5 seconds

2 seconds

1 second

instantaneous

45 minutes

5 minutes

25 seconds

5 seconds

2 seconds

1 seconds

(U.S. Government Memorandum, C.P.S.C., Peter L. Armstrong, Sept. 15,1978)

NOTE:

During low demand periods when hot water is not

being used, a lower temperature set point will reduce energy

losses and may satisfy your normal hot water needs. If hot

water use is expected to be more than normal, a higher

temperature set point may be required to meet the increased

demand.
When leaving your home for extended periods (vacations,

etc.) set the water heater to Vacation Mode. See “Adjusting the

User Interface Module/Operational Modes” section. This will

maintain the water at low temperatures with minimum energy

losses and prevent the tank from freezing during cold weather.
NOTE:

When returning from an extended stay remember to

set the water heater back to the desired Operational Mode.