Maintenance 7-7



Adjustments and Lubrication

There are no periodic adjustments required. The bearings in the motion system will self adjust to take up
any clearances as they begin to wear. The belts are fiber reinforced and will not stretch under normal use
so that periodic tension adjustment is not necessary. Optical alignment is not necessary because the
laser cartridge and the #2 Mirror are fixed.

All bearings in the system are sealed and do not require lubrication.

DO NOT lubricate the tracks that the

bearings ride in. The only lubrication that may be required is the screw threads for the table lifting
mechanism. After some time, contaminants can adhere to the lubricant, which can cause the engraving
table to bind up or sound squeaky. If this is the case, wipe off the contaminated grease with a soft cloth
and apply fresh white lithium grease to the screw threads. Run the table up and down to work in the fresh
grease.


Electronic Upgrading


The laser systems onboard computer is equipped with a special “Flash” upgrade technology. If the
electronic operation of the system should ever require upgrading, it can be done electronically without the
changing of any parts. The upgrade file gets downloaded from your computer to the laser system via the
parallel port. This file is then run on the laser system and it only takes a few minutes. Once the file has
completely run, the laser system will automatically restart and the new changes will take effect. For more
specific details, please refer to the instructions that will accompany the flash disk.

Fuse Replacement


If a fuse must be replaced, use only the following type:

USA
5 x 20 mm, Glass, time delay, 250V, 10A fuse, UL approved

Europe and other countries
5 x 20 mm, Glass, time delay, 250V, 5A fuse, designed to IEC 127-2 sheet 3, and approved by
a recognized European testing agency.

Battery Replacement

There is a danger of explosion if the battery is incorrectly replaced. Replace the
battery only with the same or equivalent type recommended by the battery
manufacturer. Using an incorrect battery, recharging or disassembling the
battery may present a danger due to fire or explosion. Dispose of used batteries
promptly according to the local regulations.