MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06

Page 32 of 68

flowserve.com

The motor must be wired up in

accordance with the motor manufacturer’s

instructions (normally supplied within the terminal

box) including any temperature, earth leakage,

current and other protective devices as appropriate.

The identification nameplate should be checked to

ensure the power supply is appropriate.

See section 5.4,

Direction of rotation,

before connecting the motor to the electrical supply.

For close coupled pumps it is necessary to wire the

motor with flexible conduit of sufficient length to allow

the motor/power end assembly to be moved back

from the casing for maintenance.

4.8 Final shaft alignment check

4.8.1 Horizontal pumps

a) Level baseplate if appropriate.

b) Mount and level pump if appropriate. Level the

pump by putting a level on the discharge flange.

If not level, adjust the footpiece as follows:

Mark 3A and ANSI 3 design

Add or delete shims [3126.1] between the

footpiece and the bearing housing.

Mark 3 design

Use the adjuster nut [6576] to adjust the

footpiece up or down.

c) Check initial alignment. If pump and driver have

been remounted or the specifications given below

are not met, perform an initial alignment as

described in section 4.5. This ensures there will

be sufficient clearance between the motor hold

down bolts and motor foot holes to move the

motor into final alignment. The pump and driver

should be within 0.38 mm (0.015 in.) FIM (full

indicator movement) parallel, and 0.0025 mm/mm

(0.0025 in./in.) FIM angular.

Stilt mounted baseplates

If initial alignment cannot be achieved with the motor

fasteners centered, the baseplate may be twisted.

Slightly adjust (one turn of the adjusting nut) the stilts

at the driver end of the baseplate and check for

alignment to the above tolerances. Repeat as

necessary while maintaining a level condition as

measured from the pump discharge flange.

d) Run piping to the suction and discharge to the

pump. There should be no piping loads

transmitted to the pump after connection is made.

Recheck the alignment to verify that there are no

significant changes.

e) Perform final alignment. Check for soft-foot under

the driver. An indicator placed on the coupling,

reading in the vertical direction, should not indicate

more than 0.05 mm (0.002 in.) movement when

any driver fastener is loosened. Align the driver

first in the vertical direction by shimming

underneath its feet.

f) When satisfactory alignment is obtained the

number of shims in the pack should be

minimized. It is recommended that no more than

five shims be used under any foot. Final

horizontal alignment is made by moving the

driver. Maximum pump reliability is obtained by

having near perfect alignment. Flowserve

recommends no more than 0.05 mm (0.002 in.)

parallel, and 0.0005 mm/mm (0.0005 in./in.)

angular misalignment. (See section 6.8.4.7.)

g) Operate the pump for at least an hour or until it

reaches final operating temperature. Shut the

pump down and recheck alignment while the pump

is hot. Piping thermal expansion may change the

alignment. Realign pump as necessary.

4.8.2 Close coupled pumps

Alignment between the pump shaft and motor shaft is

built in by precise machining of the parts that position

these shafts. Parallel alignment of 0.018 mm (0.007 in.)

and angular alignment of 0.002 mm/mm (0.002 in/in)

can be expected. If a more refined alignment is desired,

it can be accomplished with the “C-Plus” optional

alignment feature.

The C-Plus option requires that a spacer as shown in

section 8.9 be installed. Four adjusting screws are

used to push on the motor mounting studs to achieve

parallel alignment. The motor mounting fasteners

must be snug, but not tight during alignment. It may

be necessary to check the motor alignment with

motor fasteners tight. Corrections may be made until

the desired alignment is achieved. The motor

fasteners, adjusters and jam nuts should be tight.

4.8.3 In-Line pumps

The final field alignment follows the same procedure

as the initial alignment as described in section 4.5.2.

Maximum pump reliability is obtained by having near

perfect alignment. Flowserve recommends no more

than 0.05 mm (0.002 in.) parallel, and 0.0005 mm/mm

(0.0005 in./in.) angular misalignment.

4.9 Protection systems

The following protection systems are

recommended particularly if the pump is installed in a

potentially explosive area or is handling a hazardous

liquid. If in doubt consult Flowserve.