U-Line Electrical / Plumbing Specfications

11

10 Prepare Power Supply

Electrical Specifications

WARNING

SHOCK HAZARD — Electrical Grounding Required.

• Never remove the round grounding prong from the

plug and never use a two-prong grounding adapter.

• Never use an extension cord to connect power to the

unit.

IMPORTANT

IMPORTANT

Electrical installation must observe all state and local
codes. This unit requires connection to a grounded (three-
prong), polarized receptacle that has been placed by a
qualified electrician.

The unit requires a grounded and polarized 115 VAC, 60 Hz, 15A
power supply (normal household current). An individual, properly
grounded branch circuit or circuit breaker is recommended. GFCI
(ground fault circuit interrupter) is usually not required for fixed
location appliances and is not recommended for your unit because
a GFCI could be prone to nuisance tripping. However, be sure to
consult your local codes.

See below for recommended receptacle location

CLR2160 & CLRCO2175

CO29

24"

Acceptable

Location

Preferred

Location

for CLR2160

Receptacle

1"

7"

1-1/2"

7"

24"

4"

7"

24"

CO1175

CO29

CO2175FF

Receptacle Location

24"

Minimum

1-1/2"

7"

1-1/2"

7"

24"