U-Line 1075WC User Manual

Page 4

Advertising
background image

www.U-LineService.com

4

09/2008

1075WC

PRODUCT DIMENSIONS

Please note that the unit has adjustable feet that can add
one additional inch to height during leveling or to match
adjacent cabinets (see Figure 9).

DOOR SWING/CLEARANCES INFORMATION

All 1075 units have a zero clearance for the door to open
90° (see Figure 3). Stainless units require a minimum of
2" door clearance to accommodate the handle if the unit
is installed next to a wall or similar type of structure.

OTHER SITE REQUIREMENTS

Power Supply

The unit requires a grounded and polarized 115 VAC,
60 Hz, 15A circuit (normal household current). See
Electrical Specifications on Page 7.

Environmental Requirements

Many U-Line models are designed to operate in harsh
outdoor/marine environments. Special considerations
include the following:

• The units are designed to operate between 50°F (10°C)

and 110°F (40°C). High ambient temperatures (110°F
[40°C] or higher) may reduce the unit’s ability to reach
low temperatures.

• For best performance, keep the unit out of direct

sunlight and away from heat generating equipment.

• In climates where high humidity and dew points are

present, condensation may appear on outside surfaces.
This is considered normal. The condensation will
disappear when the humidity drops.

• U-Line does not recommend installation of glass front

models (Wine Captain

®

wine storage models and

Beverage Centers) as well as the Combo Drawer model
(Refrigerator/Freezer/Ice Maker) outdoors, or in
tropical climates where high humidity and dew point
are present on a regular basis, unless air-conditioning
(typical 72°F, 75%RH) will be used.

SIDE-BY-SIDE INSTALLATION INSTRUCTIONS

For a complete refreshment center, install two of the
following 1175/1075 series units side by side: 1175R,
1175WC or a 1075 BEV Center. Note that each Side-By-
Side Installation will be different.

• Cut-out width for a side-by-side installation is the total

of the widths listed under Cut-Out Dimensions in each
unit’s Installation Guide.

For example:

Placing a 1175R next to an 1075 series unit would
require a cut-out width of:
24-3/16" + 24-3/16" = 48-3/8"

• No trim kit is required. However, 1/4-inch space needs to

be maintained between the units to ensure
unobstructed door swing.

• Units must operate from separate, properly grounded

electrical receptacles placed according to each unit’s
Electrical Specifications.

34-1/8"

23-15/16"

25-7/16"

Including

Handle

ULIN_1060_A

Figure 2

Wall

2" Min.

90°

Door Swing

20-7/8"

25-1/4"

Wine Captain 1075WC

Figure 3

Advertising