Ice Cube Thickness Adjustment

Interval - As Required
The ice cube size may be adjusted by changing the
amount of water injected into the ice maker assembly as
follows:

Figure 12

1. Remove the ice maker assembly cover (Figure 12).

Figure 13

2. Locate the adjusting screw on the ice maker assembly

control box. The adjusting screw is just below the minus
(-) and plus (+) signs on the control box (Figure 13).

NOTE: Make adjustments in small increments. Too
large of an adjustment could cause the unit to
malfunction.

3. Turn the adjusting screw toward the minus (-) sign

(clockwise) for smaller cubes or toward the plus (+) sign
(counterclockwise) for larger cubes.

4. Install the ice maker assembly cover.

IMPORTANT

IMPORTANT

Use only genuine U-Line replacement parts. U-Line
ice maker parts are not the same as standard FSP
Whirlpool parts. Using non U-Line parts can reduce
ice rate, cause water to overflow from ice maker
mold, damage the unit and may void the warranty.

Leveling

IMPORTANT

IMPORTANT

It is extremely important that the unit sits on a
level surface, as it does not have feet levelers. If it
is not level, the ice mold will not fill evenly.

Use a level to check the levelness of the unit from front to
back and from side to side. Level should be placed along
top edge and side edge as shown (Figure 15, 1).

Figure 14