Troubleshooting guide – U-Line BI98 User Manual

Page 16

Advertising
background image

16

BI95, BI98, SP18

Troubleshooting Guide

DANGER

ELECTROCUTION HAZARD
Never attempt to repair or perform maintenance on
the unit until the main electrical power has been
disconnected.

Troubleshooting - What to check when problems occur:

PROBLEM

POSSIBLE CAUSE

REMEDY

The unit frosts up.

Unit is manual defrost model.

Models SP18, 95, 98, CO29 and CO75 are manual defrost
(See MAINTENANCE; DEFROSTING).

Door gasket not sealing properly

Adjust door (See MAINTENANCE; DOOR ALIGN, ADJUST,
REVERSE).

High ambient temperatures or
humidity

Defrost unit manually (See MAINTENANCE;
DEFROSTING).

Door left open

Make sure door is closed.

Water is leaking out the back of the
unit.

Water supply connection leaking

Tighten fitting as required.

Ice cubes sticking together

Door gasket not sealing properly

Adjust door (See MAINTENANCE; DOOR ALIGN, ADJUST,
REVERSE).

Infrequent use of cubes

Break apart cubes.

Noise during operation

Copper water supply tubing
contacting internal components

Carefully bend tubing away from cabinet and
components.

Certain sounds are normal.

Soft sounds from the fan and water/dropping sounds
from the ice maker will be heard.

Fan blade touching obstruction
(wiring, foam insulation, etc.)

Remove obstruction.

No ice

Bin arm locked in upright position

Lower bin arm.

No water to unit

Turn on water or contact plumber.

Not enough ice

Control set too cold

Adjust control to a warmer setting (See OPERATION).

Ice cube size too large

Set cube size smaller (See MAINTENANCE; ICE MAKER;
ICE CUBE THICKNESS ADJUST).

Dirty condenser coils

Clean condenser (See MAINTENANCE; CONDENSER
CLEANING).

Water leaks into ice bucket.

Water level set too high

Set cube size smaller (See MAINTENANCE; ICE MAKER;
ICE CUBE THICKNESS ADJUST).

Advertising