TROUBLE SHOOTING

NOTE: Negative pressure in a home is a serious issue. All American Harvest appliances should

be installed with the optional fresh air kit (69FAK).

Unplug stove before performing any maintenance

PROBLEM

CAUSE: Too rich air/fuel mixture

? Fire burns with a lazy, orange flame
and/or fuel builds up in the firepot.
Glass may become dirty.

? Fire goes out or stove shuts down.
Fuel may stop feeding.

? Fire goes out or stove shuts down.
Fuel may stop feeding.

Make sure that the manual damper
slide below the door is pulled out.
( in the open position )

Make sure glass door is shut and
sealed tightly. If not, adjust door
handle or replace gasket.

Check that exhaust fan is running
and venting properly. If not, check
connection and clean or replace.

Moisture content above 15%.
Allow fuel to dry or mix with wood
pellets.

9

9

9

9

Check inside stove and exhaust
pipes for blockage. Tap inside
walls of firebox, clean behind
lower access plates (located on
the back inside wall, next to the
firepot) clean firepot and firebox
vent holes above firebrick panel.

Feed rate is too HI for fuel, reduce
heat setting.

Inadequate combustion air
available, add outside
combustion air.
(Optional kit 69FAK)

9

9

9

CAUSE: Firepot burns out of fuel

Hopper empty, refill

Door is open

Auger jams. Remove auger and
clean. (Auger jams can be a prob-
lem if poor quality fuel is used. Or
excessive fines (sawdust, corn
cobs or husk) are found in hopper.
Auger jams are evident when there
is no fuel delivered.

9
9
9

The control board diagnostics will
flash the light above Draft Fan for
a Vacuum Switch error and dis-
play a “Err1” for a Hi Limit error.

9

CAUSE: Auger stops turning

Auger has come loose. Check to
see if auger motor is turning and
auger is not. NOTE: Auger is held
to the auger motor by a coupler
that is fastened to the auger motor.
Simply slide the auger into the
auger housing and rotate until it
fits into the coupler.

Low limit sensor.

If the operating

temperature is too low the stove
will shut down.

9

9

Hi limit sensor. Evident when
stove is extremely hot and

the

PCB displays an “Err1”

. Allow

stove to cool for 1 hour and
restart.

Vacuum switch tripped. Caused
by draft fan not running or
venting blocked. Check fan,
clean or replace. Clean venting
of blockage.

Auger motor not operating.
Inspect connection and replace
if necessary.

9

9

9

Advertising