TROUBLESHOOTING

BEFORE CALLING FOR SERVICE

If the unit appears to be malfunctioning, read through NORMAL OPER-
ATION first. If the problem persists, check the TROUBLESHOOTING
GUIDE. Locate the problem in the guide and refer to the cause and its
remedy before calling for service. The problem could be something very
simple which can be solved without a service call.

TROUBLESHOOTING GUIDE

NEVER attempt to repair or perform maintenance on the
unit until the main electrical power has been disconnected.

Troubleshooting — What to check when problems occur

Problem

Possible Cause

Remedy

The unit does

No electrical power

Make sure power cord

not operate

to the unit

is plugged in. Check for
blown fuse or tripped
circuit breaker

Cycle selector switch

Make sure cycle selector

set improperly

switch is set to ICE

Low air temperature

Surrounding air

around unit

temperature must be at
least 50°F (10°C)

Unit runs but no No water being

Check to see that water

ice is produced

supplied to the unit

is connected and turned
on to the unit

Unit runs but

Dirty condenser coils

Clean the condenser.

produces very

See CARE AND

little ice

CLEANING

High air temperature

Surrounding air

around unit

temperature of over
90°F (32°C). Low ice
production at high
temperatures is normal

Scale and mineral

Clean unit. See CARE

buildup in unit

AND CLEANING

!