Installation – Vanguard VMH26TNC User Manual

Page 17

Advertising
background image

www.desatech.com

113111-01H

17

InsTallaTIon

Continued

Installation must include an equipment shutoff
valve, union, and plugged 1/8" NPT tap. Lo-
cate NPT tap within reach for test gauge hook
up. NPT tap must be upstream from fireplace
(see Figure 22).
IMPORTANT: Install equipment shutoff valve
in an accessible location. Equipment shutoff
valve is for turning on or shutting off gas to
the appliance.
Check your building codes for any special
requirements for locating equipment shutoff
valve to fireplaces.
Apply pipe joint sealant lightly to male NPT
threads. This will prevent excess sealant from
going into pipe. Excess sealant in pipe could
result in clogged fireplace valves.

WARNING: Use pipe joint

sealant that is resistant to liquid

petroleum (LP) gas.

Figure 22 - Gas Connection

CSA Design-Certified
Equipment Shutoff Valve
With 1/8" NPT Tap*

PROPANE/LP
From External
Regulator (11" W.C.
to 14" W.C. Pressure)
NATURAL
From Gas Meter
(5" W.C. to
10.5" W.C.
Pressure)

3" Minimum

Pipe Cap Tee
Nipple

Joint

Sediment Trap

* Purchase the optional CSA design-certified
equipment shutoff valve from your dealer.

Figure 23 - Removing Log Base

Assembly From Fireplace

Branch
Support

Screen

Screen
Shipping
Screw

Shoulder
Screw

Flexible
Gas Line

CONNECTING EQUIPMENT SHUTOFF
VALVE TO HEATER CONTROL

Installation Items Needed
• Phillips screwdriver
• sealant (resistant to propane/LP gas, not

provided)

1. To remove fireplace screen, remove 2

screws that hold fireplace screen in place
for shipping. These screws are located
near top of screen. Discard screws. Lift fire-
place screen up and pull out to remove.

2. Remove screws that attach branch sup-

port to fireplace (see Figure 23). Carefully
lift up branch support and remove from
fireplace (see Figure 23).

3. Route flexible gas line included from fire-

place control to equipment shutoff valve
through side or rear access holes in outer
casing.

NOTICE: Most building codes do

not permit concealed gas con-

nections. A flexible gas line is

provided to allow accessibility

from the fireplace (see Figure 23).

The flexible gas supply line con-

nection to the equipment shutoff

valve should be accessible.

CAUTION: Avoid damage to

regulator. Hold gas regulator

with wrench when connecting it

to gas piping and/or fittings.

4. Apply pipe joint sealant lightly to male

threads of gas connector attached to flex-
ible gas line/equipment shutoff valve (see
Figure 24, page 18).

5. Check all gas connections for leaks. See

Checking Gas Connections, page 18.