Direct-vent fireplace, Venting installation, Continued – Vanguard Managed Solutions MBDV37 User Manual

Page 10

Advertising
background image

10

106497

DIRECT-VENT FIREPLACE

®

VENTING
INSTALLATION

Continued

UP

UP

Horizontal Venting

Vertical (V)

Horizontal (H)

37" min.

17" max.

Figure 16 - Horizontal Termination Con-
figuration for Rigid Venting

Figure 17 - Horizontal Termination Configuration for Rigid Venting Using One
90

°

Elbow

Figure 18 - Horizontal Termination Using Flexible Venting

Horizontal Venting

Vertical (V)

Horizontal (H)

44" min.

29" max.

(30

°

and 90

°

only, no vertical pipe)

55" min.

41" max.

(30

°

elbow, 1' vertical pipe, 90

°

elbow)

67" min.

60" max.

79" min.

84" max.

96" min.

20' max.

Note: This configuration for use with
corner installation.

UP

Horizontal Venting

See information in
Figure 17 for
Vertical(V) and
Horizontal(H)
maximums and
minimums. The
same amounts
apply for flexible
venting.

Note: Figure 16
applies to rigid
venting only.

GFVK Vent Kit Shown
(recommended for use
with cabinet mantels)

BFGFVK and FGFVK
Vent Kits Shown

Horizontal Termination
Configurations

Figures 16 through 20 show different con-
figurations for venting with horizontal ter-
mination. Each figure includes a chart with
vertical minimum/maximum and horizon-
tal maximum dimensions which must be
met. Seal all connections with high tem-
perature silicone sealant (outer pipe only) as
specified in the second warning statement
on page 7. All horizontal terminations re-
quire 1/4" rise per 12" of horizontal run.

MDVGFK Vent Kit Shown