Vent-free natural gas heater, Operating heater, Lighting instructions – Vanguard Heating VN1800ITB User Manual

Page 12: For your safety read before lighting

Advertising
background image

12

104246

VENT-FREE NATURAL GAS HEATER

®

IGNITOR

PILOT

LO

OFF

HI

1

2

3

4

Figure 17 - Pilot

Pilot Burner

Thermocouple

Ignitor Electrode

LIGHTING

INSTRUCTIONS

1.

STOP! Read the safety information
at the top column 1.

2.

Make sure equipment shutoff valve
is fully open.

3.

Turn thermostat control knob on left
side of heater clockwise

Clockwise

to

the OFF position.

4.

Wait five minutes to clear out any gas.
Then smell for gas, including near the
floor. If you smell gas, STOP! Follow
“B” in the safety information at the
top of column 1. If you don’t smell gas,
go to the next step.

5.

Turn thermostat control knob on left side
of heater counterclockwise

C-clockwise

to

the PILOT position. Press in thermostat
control knob for 5 seconds.

Note:

You may be running this

heater for the first time after hook-
ing up to gas supply. If so, you may
need to press in thermostat control
knob for 30 seconds. This will allow
air to bleed from the gas system.
• If thermostat control knob does

not pop up when released, contact
a qualified service person or gas
supplier for repairs.

Plaque Control Knob

Thermostat Control Knob

Ignitor Button

Figure 16 - Thermostat Control Knob In The OFF Position

6.

Keep thermostat control knob
pressed in while pushing down and
releasing the ignitor button. This will
light pilot. If necessary, continue to
press ignitor button until pilot lights.

If pilot does not light
• turn thermostat control knob

clockwise

Clockwise

to the OFF po-

sition

• repeat steps 5 and 6

If pilot does not stay lit after several
tries
• refer to Troubleshooting
, pages 15

through 17

• contact a qualified service person

or gas supplier

Until repairs are made, light pilot with
match. To light pilot with match, see
Manual Lighting Procedure
, page 13

7.

Keep thermostat control knob
pressed in for 30 seconds after light-
ing pilot. After 30 seconds, release
control knob.

Note:

If pilot goes out, repeat steps

3 through 7. This heater has a safety
interlock system. Wait one minute
before lighting pilot again.

8.

Turn thermostat control knob coun-
terclockwise

C-clockwise

to the desired

heating level. The plaque directly
above the pilot should light.

OPERATING
HEATER

FOR YOUR SAFETY

READ BEFORE

LIGHTING

WARNING: If you do not fol-

low these instructions exactly, a
fire or explosion may result caus-
ing property damage, personal
injury or loss of life.

A. This appliance has a pilot which must

be lighted by hand. When lighting the
pilot, follow these instructions exactly.

B. BEFORE LIGHTING smell all

around the appliance area for gas. Be
sure to smell next to the floor because
some gas is heavier than air and will
settle on the floor.

WHAT TO DO IF YOU SMELL
GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do

not use any phone in your building.

• Immediately call your gas supplier

from a neighbor’s phone. Follow
the gas supplier’s instructions.

• If you cannot reach your gas sup-

plier, call the fire department.

C. Use only your hand to push in or turn

the gas control knob. Never use tools.
If the knob will not push in or turn
by hand, don’t try to repair it, call a
qualified service technician or gas
supplier. Force or attempted repair
may result in a fire or explosion.

D. Do not use this appliance if any part

has been under water. Immediately
call a qualified service technician to
inspect the appliance and to replace
any part of the control system and
any gas control which has been un-
der water.

Advertising