26 - User's Manual

System Time

Keep current date and time: Select this option to reserve the current date and time of the Network
Camera. The Network Camera’s internal real-time clock maintains the date and time even when the
power of the system is turned off.

Sync with computer time: Select this option to synchronize the date and time of the Network Camera with
the local computer. The read-only date and time of the PC is displayed as updated.

Manual: The administrator can enter the date and time manually. Note that the date and time format are
[yyyy/mm/dd] and [hh:mm:ss].

Automatic: The Network Time Protocol is a protocol serves synchronize computer clocks by periodically
querying an NTP Server.

NTP server: Assign the IP address or domain name of the time-server. Leaving the text box blank
connects the Network Camera to the default time-servers.

Update interval: Select to update the time with the NTP server on hourly, daily, weekly, or monthly basis.

Time zone Advanced mode : According to your local time zone, select one from the drop-down list. If
you want to upload the daylight saving time rules on Maintenance page, please refer to Upload / Export
Daylight Saving Time Configuration File on page 71 for details.

DI and DO

Digital input: Select High or Low to define normal status of the digital input. The Network Camera will
report the current status.

Digital output: Select Grounded or Open to define normal status of the digital output. The Network
Camera will show whether the trigger is activated or not.