Infrared natural gas heater, Troubleshooting – Vanguard Heating VN1800TB User Manual

Page 14

Advertising
background image

14

104820

INFRARED NATURAL GAS HEATER

®

TROUBLESHOOTING

OBSERVED PROBLEM

When ignitor button is pressed in, there is no
spark at ODS/pilot

ODS/pilot lights but flame goes out when
control knob is released

POSSIBLE CAUSE

1. Ignitor electrode positioned wrong
2. Ignitor electrode broken
3. Ignitor electrode not connected to igni-

tor cable

4. Ignitor cable pinched or wet

5. Broken ignitor cable
6. Bad piezo ignitor

7. Piezo ignitor nut is loose

1. Gas supply turned off or equipment

shutoff valve closed

2. Control knob not fully pressed in while

pressing ignitor button (non-thermostat
models only)
Thermostat control knob not fully
pressed in while pressing ignitor button
(thermostat models only)

3. Air in gas lines when installed

4. ODS/pilot is clogged

5. Gas regulator setting is not correct
6. Thermostat control knob not in pilot

position

REMEDY

1. Replace ignitor
2. Replace ignitor
3. Reconnect ignitor cable

4. Free ignitor cable if pinched by any

metal or tubing. Keep ignitor cable dry

5. Replace ignitor cable
6. Replace control valve (piezo is part of

control valve)

7. Tighten nut holding piezo ignitor. Nut

is located inside heater cabinet at top

1. Turn on gas supply or open equipment

shutoff valve

2. Fully press in control knob while press-

ing ignitor button (non-thermostat mod-
els only)
Fully press in thermostat control knob
while pressing ignitor button (thermo-
stat models only)

3. Continue holding down control knob.

Repeat igniting operation until air is re-
moved

4. Clean ODS/pilot (see Cleaning and

Maintenance, page 13 ) or replace ODS/
pilot assembly

5. Replace gas regulator
6. Turn thermostat control knob to pilot

position

WARNING: Turn off and un-

plug heater and let cool before
servicing. Only a qualified ser-
vice person should service and
repair heater.

CAUTION: Never use a wire,

needle, or similar object to clean
ODS/pilot. This can damage ODS/
pilot unit.

www.desatech.com

Note:

For additional help, visit DESA

International’s technical service web site
at

www.desatech.com

.

Note:

All troubleshooting items are listed in

order of operation.

Advertising
This manual is related to the following products: