- 18 -

2) Condensing unit shall be elevated to avoid possible

flooding and shaded from direct sun. It shall not be
exposed to temperatures higher than 110 °F or lower than
50 °F.

3) Leave minimum 5 ft clearance for the exhaust side and

leave minimum 1 foot clearance for the ambient air intake
side.

4) Service valve operations

1 - Process & Manometer
2 – Receiver Discharge or Compressor Suction
3 – Liquid Line or Suction Line
4 - Pressure Control
Back Position
: Normal operation, process and manometer port closed
Front Position
: Liquid/suction line connection closed
Middle Position: All ports open for evacuation, charge and manometer

BACK POSITION FRONT POSITION MIDDLE POSITION

Fig. 9 ROTALOCK Valve Operation

BACK POSITION FRONT POSITION MIDDLE POSITION

Fig. 10 Base Valve Operation


4. Temperature Controller and Air Probe

1) The temperature controller can be mounted either inside or outside the wine

cellar, but the air probe must be located inside the wine cellar or the return
duct.