General Format of Command URL

Every configuration can be set through URL with the POST method by the
Administrator only.
<general format>
URL[?[name=value][&name=value]… … ]
<method>
POST
<authorized user>
root

System Configuration URL

URL:

/setup/system.cgi

NAME

VALUE

DESCRIPTION

host

<text string shorter than 15
characters>

system name

yes

turn off front LED

ledoff

no

turn off front LED

keep

keep date and time unchanged

auto

use NTP server to synchronize

method

manu

directly adjust date and time

date

<yyyy/mm/dd>

year, month and date separated by
slash

time

<hh:mm:ss>

hour, minute and second separated
by colon

ntp

<domain name or IP address> NTP server

zone

-12 ~ 12

time zone, 8 means GMT +8:00

one hour

Synchronize with NTP hourly

one day

Synchronize with NTP daily

one week

Synchronize with NTP weekly

updateInterval

One month

Synchronize with NTP monthly