• It may use fan speed control to adjust the system refrigeration

performance to achieve 8-10

°

F differential between return air and supply

air. In order to control fan speed properly,
a minimum speed adjustment is required.
Turn main control knob to lowest speed
position, locate the setting (on the side or
front) and adjust minimum speed setting
with screw driver (rotate clockwise to
decrease minimum speed; counter-
clockwise to increase minimum speed).
The fan will run from this preset minimum
speed to full speed.

• Suction pressure: 30-35 psig
• Head pressure: 125-150 psig at 70 -90

°

F ambient temperatures


The line sizes and refrigerant charges are listed as follows.

MODEL

REFRIGERATION

LINES

LIQUID

LINE

SUCTION

LINE

DRAIN

LINE

CHARGE

VINO-

1500SSW

<= 50 FT

1/4"

OD

3/8” OD

1/2” OD

R134a/

15 OZ

VINO-

2500SSW

<= 50 FT

1/4"

OD

3/8” OD

1/2” OD

R134a/

19 OZ


NOTES:
THE VALVE CONNECTION SIZES OF CONDENSING UNIT AND THE LINE

CONNECTION SIZES OF EVAPORATOR UNIT ARE NOT NECESSARY
THE SAME AS THE ABOVE SPECIFIED LINE SIZES.

IF THE CONDENSING UNIT IS INSTALLED ABOVE THE EVAPORATOR

UNIT, USE THE SUCTION LINE ONE LISTED SIZE SMALLER.

EXPANSION AND SOLENOID VALVES ARE INSTALLED ON LIQUID LINE.

6. Pressure, Superheat and Subcooling Readings


CAUTION:
THE VALVES MUST BE IN THE MIDDLE POSITIONS TO READ PROPERLY.

Complaint Possible

Causes

a. High suction pressure and low head pressure
b. High suction pressure and low head pressure
Low superheat and low subcooling
c. High suction pressure and high head pressure
Low superheat and high subcooling
d. High to normal suction pressure and high head pressure
Low subcooling
e. High suction pressure and high head pressure
Low subcooling
f.

High suction pressure and high head pressure

High superheat

a. Compressor may be bad
b. Expansion valve opened, too

much oil

c. Overcharge

d. Non-condensable

gas


e. Air restricted, dirty condenser,

bad condenser fans

f. High room temperature, high

evaporator load

Advertising