Owner’s manual, Troubleshooting – Vanguard Heating SBVRBP User Manual

Page 23

Advertising
background image

23

106707

OWNER’S MANUAL

For more information, visit www.desatech.com

TROUBLESHOOTING

Note:

All troubleshooting items are listed in

order of operation.

WARNING: Turn off burner

system and let cool before ser-
vicing. Only a qualified service
person should service and repair
heater.

CAUTION: Never use a wire,

needle, or similar object to clean
pilot. This can damage pilot unit.

POSSIBLE CAUSE

1. Ignitor electrode not connected to igni-

tor cable

2. Ignitor cable pinched or wet

3. Piezo ignitor nut is loose

4. Broken ignitor cable
5. Bad piezo ignitor
6. Ignitor electrode broken
7. Ignitor electrode positioned wrong

1. Gas supply turned off or equipment

shutoff valve closed

2. Control knob not in PILOT position
3. Control knob not pressed in while in

PILOT position

4. Air in gas lines when installed

5. Depleted gas supply (propane/LP mod-

els only)

6. Pilot is clogged

7. Gas regulator setting is not correct

1. Control knob not fully pressed in
2. Control knob not pressed in long enough

3. Equipment shutoff valve not fully open
4. Control valve damaged

REMEDY

1. Reconnect ignitor cable

2. Free ignitor cable if pinched by any

metal or tubing. Keep ignitor cable dry

3. Tighten nut holding piezo ignitor. Nut

is located behind the mounting bracket.

4. Replace ignitor cable
5. Replace piezo ignitor
6. Replace pilot assembly
7. Replace pilot assembly

1. Turn on gas supply or open equipment

shutoff valve

2. Turn control knob to PILOT position
3. Press in control knob while in PILOT

position

4. Continue holding down control knob.

Repeat igniting operation until air is
removed

5. Contact local propane/LP gas company

6. Clean pilot (see Cleaning and Mainte-

nance, page 22) or replace pilot assembly

7. Replace gas control

1. Press in control knob fully
2. After pilot lights, keep control knob

pressed in 30 seconds

3. Fully open equipment shutoff valve
4. Replace control valve

OBSERVED PROBLEM

When ignitor button is pressed, there is no
spark at pilot

When ignitor button is pressed, there is
spark at pilot but no ignition

Pilot lights but flame goes out when control
knob is released

Note:

For additional help, visit DESA

International’s technical service web
site at

www.desatech.com

.

www.desatech.com

Continued

Advertising