Operating heater, Caution – Vanguard Managed Solutions VP1000B User Manual

Page 17

Advertising
background image

17

099406

4. Wait five (5) minutes to clear out any gas. Then smell for gas, including

near the floor. If you smell gas, STOP! Follow “B” in the safety information
at the top of page 16. If you don’t smell gas, go to the next step.

5. Press in control knob and turn counterclockwise

C-clockwise

to the PILOT

position. Keep control knob pressed in for five (5) seconds (see Figure 16,
page 16).

Note:

You may be running this heater for the first time after hooking up

to gas supply. If so, the control knob may need to be pressed in for 30
seconds. This will allow air to bleed from the gas system.

• If control knob does not pop up when released, contact a qualified

service person or gas supplier for repairs.

6. With control knob pressed in, push down and release ignitor button. This

will light pilot. The pilot is attached to the front of burner. The pilot can be
seen through the glass panel. If needed, keep pressing ignitor button until
pilot lights.

Note:

If pilot does not stay lit, refer to Troubleshooting, pages 20 through

23. Also contact a qualified service person or gas supplier for repairs.
Until repairs are made, light pilot with match. To light pilot with match,
see Manual Lighting Procedure
, page 18.

Continued

OPERATING

HEATER

Continued

Thermocouple

Pilot Burner

Ignitor Electrode

Figure 17 - Pilot

7. Keep control knob pressed in for 30 seconds after lighting pilot. After 30

seconds, release control knob.

Note:

If pilot goes out, repeat steps 3 through 7.

8. Turn control knob counterclockwise

C-clockwise

to the HIGH position. The

main burner should light. Set control knob to any heat level between HIGH
and LOW. To turn control knob from HIGH to a lower setting, press in the
control knob and turn counterclockwise

C-clockwise

.

Note:

Both HIGH and LOW are locked positions. You must press in control

knob before turning it from these positions.

WARNING ICON

G 001

CAUTION

Do not try to adjust heating levels by using the manual shutoff valve.