Technical service, Service hints, Specifications – Vanguard Managed Solutions VP1000B User Manual

Page 24

Advertising
background image

24

099406

You may have further questions about installation, operation, or troubleshooting.
If so, contact DESA International’s Technical Service Department at 1-800-323-
5190.

TECHNICAL

SERVICE

SPECIFICATIONS

BTU (Variable)

5,000/10,000

Type Gas

Propane Only

Ignition

Piezo

Pressure Regulator Setting

8" W.C.

Inlet Gas Pressure (inches of water)

Maximum

14"

Minimum

11"

Dimensions, Inches (H x W x D)

Heater

20 1/2 x 13 1/2 x 5

Carton

25 x 16 11/16 x 7 1/2

Weight (pounds)

Heater

13.5

Shipping

16.5

When gas pressure is too low

• pilot will not stay lit
• burner will have delayed ignition
• heater will not produce specified heat
• propane gas supply may be low

When gas quality is bad

• pilot will not stay lit
• burner will produce flames and soot
• heater will backfire when lit

You may feel your gas pressure is too low or gas quality is bad. If so, contact your
local propane gas supplier.

SERVICE

HINTS

Advertising