Installation, Continued – Vanguard Heating VMH26TPB User Manual

Page 12

Advertising
background image

111043-01A

For more information, visit www.desatech.com

For more information, visit www.desatech.com

12

3
2
1

3.

Note the wire locations on back of AUTO/OFF/ON switch.
The terminals on back of switch are numbered 1, 2, and 3.
Carefully remove red wire from terminal 1 and blue wire from
terminal 3. Black wire can remain on middle terminal 2 (see
Figure 18).

4.

Carefully disconnect green and white wires at their insulated
connectors.

5.

In top of the heater cabinet, locate the four mounting holes on
the outer casing. Align these four holes with those on the blower
bracket assembly. Attach blower bracket assembly to the outer
casing with 4 #10 screws provided (see Figure 18).

6.

Route the wire harness through the hole in left side of baffle.
Pull wire harness through lower opening above where the
valve shield was removed. (see Figure 18).

7.

Insert the 4 wire harness into one of the round holes in the rear
of the valve cover shield and through the rectangular hole in
the front of shield (see Figure 18).

8.

Reconnect red wire to switch position 3. Reconnect blue wire
to switch position 1. Reconnect green and white wires.

Figure 18 - Installing Blower Bracket Assembly

INSTALLATION

Continued

Removing Valve Cover Shield

1.

Open bottom louver assembly by swinging the assembly down
(see Figure 17).

2.

Using short Phillips screwdriver, remove the screw under the
center of the branch support. Rotate valve cover shield clock-
wise and slide out.

IMPORTANT:

Do not remove shoulder screw on the left side

of valve cover shield. Slide the valve cover shield off of the
shoulder screw (see Figure 17).

Note:

If you do not have a short Phillips screwdriver, the

screen, log set, and branch support must be removed so a longer
screwdriver may be used. See Connecting Equipment Shutoff
Valve to Heater Control
, page 15, steps 1 and 2.

Figure 17 - Removing Valve Cover Shield

Installing Blower Assembly

CAUTION: Label all wires prior to disconnection

when servicing controls. Wiring errors can cause
improper and dangerous operation.

CAUTION: Verify proper operation after servicing.

Note:

If you are using a mantel with your heater, use the following

instructions. If your heater is built-in, see For Built-In Installation
on page 13.

1.

Install snap bushings found in hardware kit into both holes in
rear of valve cover shield.

2.

Make sure the wire harness is firmly connected to the terminals
on the blower bracket assembly.

1

2

Remove
Screw

Valve Cover
Shield

Shoulder Screw

Branch Support

Snap Bushings

Bottom Louver
Assembly

Wire
Harness

Blower Bracket
Assembly

Screw

Power
Cord

Valve Cover
Shield

Box Cover

Wire
Harness

Switch
Plate

Switch

Baffle

Wiring Routing
Hole in Baffle

Blue

Red

INSTALLATION

Installing Blower Accessory - GA3450T (Cont.)

Advertising