Installation, Continued – Vanguard Heating VMH26TPB User Manual

Page 14

Advertising
background image

111043-01A

For more information, visit www.desatech.com

For more information, visit www.desatech.com

14

CONNECTING TO GAS SUPPLY

WARNING: A qualified service person must con-

nect fireplace to gas supply. Follow all local codes.

CAUTION: Never connect propane/LP fireplace

directly to the propane/LP supply. This fireplace
requires an external regulator (not supplied). Install
the external regulator between the fireplace and
propane/LP supply.

CAUTION: Use only new, black iron or steel pipe.

Internally-tinned copper tubing may be used in cer-
tain areas. Check your local codes. Use pipe of 1/2"
or greater diameter to allow proper gas volume to
fireplace. If pipe is too small, undue loss of volume
will occur.

WARNING: Use pipe joint sealant that is resistant

to liquid petroleum (LP) gas.

For propane/LP units, installer must supply an external regulator.
The external regulator will reduce incoming gas pressure. You
must reduce incoming gas pressure to between 11 and 14 inches of
water. If you do not reduce incoming gas pressure, fireplace
regulator damage could occur. Install external regulator with the
vent pointing down as shown in Figure 23. Pointing the vent down
protects it from freezing rain or sleet.

Propane/LP
Supply Tank

External Regulator

ATTACHING WOOD BASE TO SOLID FLOOR

For attaching base to solid floors (concrete or masonry)

Note:

Floor anchors and mounting screws are in hardware package.

The hardware package is provided with fireplace.

1.

Drill holes at marked locations using 5/16" drill bit. For solid
floors (concrete or masonry), drill at least 1" deep.

2.

Fold floor anchor as shown in Figure 22.

3.

Insert floor anchor (wings first) into hole. Tap anchor flush to
floor.

4.

Insert mounting screws through base and into floor anchors.

5.

Tighten screws until base is firmly fastened to floor.

Figure 22 - Folding Anchor

Installation must include a equipment shutoff valve, union, and
plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge
hook up. NPT tap must be upstream from fireplace (see Figure 24,
page 15).

IMPORTANT:

Install equipment shutoff valve in an accessible

location. The equipment shutoff valve is for turning on or shutting
off the gas to the appliance.

Check your building codes for any special requirements for locating
equipment shutoff valve to fireplaces.

Apply pipe joint sealant lightly to male NPT threads. This will
prevent excess sealant from going into pipe. Excess sealant in pipe
could result in clogged fireplace valves.

Figure 23 - External Regulator with Vent Pointing Down

Vent Pointing Down

WARNING: This appliance requires a 45° male flare

fitting 5/8"-18 UNF (Unified National Fine Thread) inlet
connection and the flexible gas line provided.

INSTALLATION

Continued

Extension Cord

Use extension cord if needed. The cord must have a three-prong,
grounding plug and a three-hole receptacle. Make sure cord is in good
shape. It must be heavy enough to carry the current needed. An
undersized cord will cause a drop in line voltage. This will result in
loss of power and overheating. Use a No. 16 AWG cord for lengths
less than 50 feet.

WARNING: Never connect natural gas fireplace to

private (non-utility) gas wells. This gas is commonly
known as wellhead gas.

INSTALLATION

Installing Blower Accessory - GA3450T (Cont.)
Attaching Wood Base to Solid Floor
Connecting to Gas Supply

Advertising
This manual is related to the following products: