Propane/lp gas residential heaters, Troubleshooting, Continued – Vanguard Heating VMH3000TPSA User Manual

Page 18

Advertising
background image

18

107102

PROPANE/LP GAS RESIDENTIAL HEATERS

®

For more information, visit www.desatech.com

TROUBLESHOOTING

Continued

WARNING: If you smell gas

• Shut off gas supply.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your

building.

• Immediately call your gas supplier from a neighbor’s phone. Follow the

gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire department.

IMPORTANT:

Operating heater where impurities in air exist may create odors. Cleaning

supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles,
etc., create fumes. These fumes may mix with combustion air and create odors.

OBSERVED PROBLEM

Heater produces a clicking/ticking noise
just after burner is lit or shut off

Heater produces unwanted odors

Heater shuts off in use (ODS operates)

Gas odor even when control knob is in OFF
position

Gas odor during combustion

POSSIBLE CAUSE

1. Metal expanding while heating or con-

tracting while cooling

1. Heater burning vapors from paint, hair

spray, glues, etc. (see

IMPORTANT

statement above)

2. Gas leak.

See Warning statement at

top of page

1. Not enough fresh air is available
2. Low line pressure
3. ODS/pilot is partially clogged

1. Gas leak.

See Warning statement at

top of page

2. Control valve defective

1. Foreign matter between control valve

and burner

2. Gas leak.

See Warning statement at

top of page

REMEDY

1. This is common with most heaters. If

noise is excessive, contact qualified ser-
vice person

1. Ventilate room. Stop using odor caus-

ing products while heater is running

2. Locate and correct all leaks (see Check-

ing Gas Connections, page 13)

1. Open window and/or door for ventilation
2. Contact local propane/LP company
3. Clean ODS/pilot (see Cleaning and

Maintenance, page 19)

1. Locate and correct all leaks (see Check-

ing Gas Connections, page 13)

2. Replace control valve

1. Take apart gas tubing and remove for-

eign matter

2. Locate and correct all leaks (see Check-

ing Gas Connections, page 13)

www.desatech.com